AR-6020V ADJUSTMENTS 5 – 2
If the distance is not within the specified range, loosen the fix-
ing screw A of the main pole adjustment plate, and move the
adjustment plate in the arrow direction to adjust.
1-C Developing bias voltage adjustment
NOTE: Use a digital multi-meter with an internal resistance of
10Mohm or more.
1) Execute SIM 8-1.
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value, and the display returns
to the original state.
<SIM8-1>
1-D Grid bias voltage adjustment
NOTE: Use a digital multi-meter with an internal resistance of
10Mohm or more.
1) Execute SIM 8-2.
2) Touch the exposure mode to be changed.
The current set value is displayed.
3) Enter the set value with the 10-key.
4) Press the [START] key.
Output is made with the entered value, and the display returns
to the original state.
<SIM8-2>
LED Output mode
Setting
range
Default
AUTO indicator COPY 0 - 650 400
TEXT indicator COPY-TSON 0 - 650 320
PHOTO indicator PRINTER 0 - 650 400
TEXT indicator & PHOTO
indicator
PRINTER-TSON 0 - 650 400
2
3
4
LED Output mode
Setting
range
Default
AUTO indicator COPY 0 - 750 540
TEXT indicator COPY-TSON 0 - 750 460
PHOTO indicator PRINTER 0 - 750 540
TEXT indicator & PHOTO
indicator
PRINTER-TSON 0 - 750 540
2
3
4