AR-M350 SIMULATIONS 10-3
22 11 Used to check the use frequency of FAX. (send/receive)
(Only when FAX is installed.)
Adjustment, setup,
operation data output,
check (display)
FAX Data
12 Used to check the misfeed position and the number of misfeed
at that position. (If the number of misfeed is considerably great,
the machine must be repaired.)
Adjustment, setup,
operation data output,
check (display)
DSPF Trouble Misfeed
13 Used to display the process cartridge data. Adjustment, setup,
operation data output,
check (display)
Counter
19 Used to display the scanner mode counter. Adjustment, setup,
operation data output,
check (display)
Counter
24 1 Used to clear the misfeed counter, misfeed history, trouble
counter, and trouble history. (After completion of maintenance,
these counters must be cleared.)
Data clear Counter
2 Used to clear the number of use (print quantity) of each paper
feed section.
Data clear Paper feed Counter
3 Used to clear the number of use of the staple, ADF, RADF, SPF,
DSPF, and the scanner (reading) unit.
Data clear Counter
4 Used to reset the maintenance counter. Data clear Counter
5 Used to reset the developer counter.
(The developer counter of the DV unit installed is reset.)
Data clear Process (OPC drum,
developing, transfer,
cleaning)
Counter Developer
(DV unit)
6 Used to reset the copy counter. Data clear Counter Copy
7 Used to clear the OPC drum counter and the toner cartridge
counter. (Perform when the OPC drum is replaced.)
Data clear Process (OPC drum,
developing, transfer,
cleaning)
Counter OPC drum
9 Used to clear the printer print counter. (After completion of
maintenance, this counter must be cleared.)
Data clear Printer Counter Printer
10 Used to clear the FAX counter. (After completion of
maintenance, this counter must be cleared.)
(Only when FAX is installed.)
Data clear FAX Counter
11 Used to reset the drum rotation time, toner motor rotation time,
and developer rotation time counters.
The developer counter of the DV unit installed is reset.
Data clear Process (OPC drum,
developing, transfer,
cleaning)
Counter Developer
(DV unit)
15 Used to clear each counter in the scanner mode. Data clear Counter
25 1 Used to check the operations of the main drive section
(excluding the scanner (reading) section) and the toner density
sensor. (The toner density sensor output can be monitored.)
Operation test, check Drive Operation
2 Used to initialize the toner density when replacing developer.
(Auto adjustment)
Setup Process (OPC drum,
developing, transfer,
cleaning)
26 3 Used to set the specification mode of the auditor. Setup must
be made according to the use condition of the auditor.
Setup Auditor Spec
5 Used to set the count mode of the total counter and the
maintenance counter.
Setup Spec Counter
6 Used to set the specification according to the destination. Setup Spec Destination
10 Used to set the trial mode of the network scanner. Setup Operation
18 Used to set Enable/Disable of toner save operation.
(This simulation is enabled only in Japan and UK versions.
(Depends on SIM 26-6 (Destination) setup).
For the other destinations, user program P22 allows to make
the similar setup.)
Setup Spec Operation
mode
(Common
operation)
30 Used to set the operation mode conforming to the CE mark
(Europe standards).
(For flickers when driving the fusing heater lamp.)
Setup Spec Operation
mode
(Common
operation)
35 Used to set whether the trouble history of SIM 22-4 is displayed
as one-time trouble or continuous troubles when two or more
number of a same trouble occurred.
Setup Spec
38 Used to stop printing when developer life is expired. Setup Other Operation
Code
Function (Content) Purpose Section Item
Main Sub
!"#$%&