AR-M350 SIMULATIONS 10-7
66 1 Used to set the FAX soft switch function. (Used to utilize the
FAX soft switch function.)
Setup Fax
2 Used to set the FAX soft switch setup to the default.
(Except for the adjustment values)
Data clear Fax Data
3 Used to check the operations of FAX PWB memory
(read/write). (This adjustment is required when replacing the
PWB with a new one.)
Operation test, check Fax Data
4 Used to check the operations of data signal output in the FAX
data output mode.
(Used to check the MODEM operation.)
Send level 0dB (Max.) (Only when FAX is installed.)
Operation test, check Fax Operation
5 Used to check the operations of data signal output in the FAX
data output mode.
(Used to check the MODEM operation.)Signals are sent in the
send level set with the soft switch. (Only when FAX is installed.)
Operation test, check Fax Operation
6 Used to print the confidential password.
(Used when the confidential password is forgotten.)
(Only when FAX is installed.)
User data output, check
(display, print)
Fax Data
7 Used to print the image memory data (memory send, receive).
(Only when FAX is installed.)
User data output, check
(display, print)
Fax Data
8 Used to check the output operation of the FAX sound signals.
(Sound output IC operation check) Send level 0dB (Max.)
(Only when FAX is installed.)
Operation test, check Fax Operation
9 Used to check the output operation of the FAX sound signals.
(Sound output IC operation check)
(Only when FAX is installed.)
Operation test, check Fax Operation
10 Used to clear all data of image memory
(memory send, receive). Confidential data are also cleared.
(Only when FAX is installed.)
User data output, check
(display, print)
Fax Data
11 Used to check the output operation of FAX G3 mode 300BPS.
(Used to check the MODEM operation.)
Send level 0dB (Max.) (Only when FAX is installed.)
Operation test, check Fax Operation
12 Used to check the output operation of FAX G3 mode 300BPS.
(Used to check the MODEM operation.) Signals are sent in the
send level set with the soft switch. (Only when FAX is installed.)
Operation test, check Fax Operation
13 Used to enter (set) the number for the FAX dial signal output
test.
(The dial number signal set with this simulation is outputted in
the dial signal output test with SIM 66-14~16)
(Only when FAX is installed.)
Setup Fax Data
14 Used to set the make time in the FAX pulse dial mode (10PPS)
and to test the dial signal output.
(The dial number signal set with SIM 66-13 is outputted.)
Used to check dialing troubles and the operation.
(Only when FAX is installed.)
Setup Fax Operation
Code
Function (Content) Purpose Section Item