AY-M09AE
AE-M18AE
Cycle temperature and service port pressure
(ISO Cooling and heating condition)
1 unit running
NO. condition
NO. condition
88˚C
42˚C
9˚C
13˚C
0.47MPa
Service port pressure
Gauge pressure
1
2
3
4
2 units running
90˚C
47˚C
10˚C
10˚C
0.48MPa
Cooling
1 unit running
89˚C
3˚C
39˚C
0˚C
1.78MPa
Service port pressure
Gauge pressure
1
2
3
4
2 units running
88˚C
2˚C
41˚C
-1˚C
1.75MPa
Heating
ISO Cooling and Heatpump condition
Indoor side
Dry-bulb temp. (˚C) Relative humidity (%)
27
20
Cooling
Heating
47
37
Outdoor side
Dry-bulb temp. (˚C) Relative humidity (%)
35
7
40
87
Dimension of Capillary tube
O.D. I.D. L
Capillary tube A
ø 2.7 ø 1.5 350
Capillary tube B
ø 2.7 ø 1.5 500