EasyManua.ls Logo

Sharp AY-M09AE - Performance Curves

Sharp AY-M09AE
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
AY-M09AE
AE-M18AE
PERFORMANCE CURVES
Figure P-2. At Cooling for AY-M18AE (2 units running)
Figure P-1. At Cooling for AY-M09AE (1 unit running)
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
5100
6800
8500
10200
11900
Cooling capacity(BTU/h)
1.5
2.0
2.5
3.0
3.5
(kW)
700
15
14
Input(W)
13
12
11
10
9
8
7
Outside air temp.(˚C)
Outlet air temp.(˚C)
25 30 35 40 25 30 35 40
Power source : 1ø 220V, 50Hz
Indoor air temp. : 27˚C
Indoor humidity : 47RH%
Indoor fan speed : Hi
5100
6800
8500
10200
11900
Cooling capacity(BTU/h)
1700
1.5
2.0
2.5
3.0
3.5
(kW)
Input(W)
Outside air temp.(˚C)
Outlet air temp.(˚C)
Power source : 1ø 220V, 50Hz
1000
1300
2300
2000
Cooling capacity per 1 unit
15
14
13
12
11
10
9
8
7

Related product manuals