EasyManua.ls Logo

Sharp C6400U - Page 141

Sharp C6400U
191 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LC-52/60/70LE640U/C6400U,LC-80LE633U/844U (1st Edition)
6 – 23
4) Other failure details (Flashes slowly 4 times and flashes fast) Note
Error type Center icon LED operation
Pins are monitor microprocessor pins unless other-
wise specified.
Monitor temperature
failure
Flashes fast once
H: On
L: Off
If the panel temperature is 60°C or more for 15 seconds
or more in a row, CAUTION appears on the OSD
(flashes in red in the lower right screen).
If the panel temperature is 60°C or more for 25 seconds
or more in a row, error standby is activated.
(MONITOR MAX TEMP on page 15 of the process A:
Change of temperature failure AD value): Thermistor
Main failure
Flashes fast 3 times
H: On
L: Off
Main microprocessor detection error (CPU temperature
error, etc.)
The details are displayed on page 1 of the process A of
the main microprocessor.

Table of Contents