[1] Test Mode
1. Enter the Test Mode version display
While pressing down ON/STANDBY and VOL UP button, Switch ON AC supply.
Version will be display on 7 segment as below:-
b2 --> ** --> D
b2 = Model name, ( SB200 )
** = Software version no.
D = Destination code :- O (for Others), I (for Indonesia)
2. Enter the Test Mode version display
After enter Test Mode version display, Press VOL UP button.
1. All SOUND MODE LED will light ON
2. 7 segment display will light on if press button as below
3. Exit the Test Mode
While in Test Mode function, Press ON/STANDBY button to exit.
4. Error Code Description.
5. System Protection indicator
In case abnormal power detection has occurred, the unit will automatically enter to stand-by mode
ON/STANDBY LED willl be flashing as below:-
Unit enter Protect mode when irregular process occur on power supply line.
Key 7 segment
VOL DOWN 01
VOL UP 02
SURROUND 03
FUNCTION 04
Display Explanation Solution
E1 Communication error between Micom and WM877
> Unplug AC cord and turn power ON again
> Check line connected between Micom and corresponding ICE2 Communication error between Micom and NJU-26040
E3 Communication error between Micom and STA333
Flashing
OFF OFF
1 Frame
Flashing
(Repeat)