E-10
REPLACING THE FUSE
SPECIFICATIONS
*1
Space corresponding to a cabin measuring 1.5 (width) x 2.4 (depth) x 1.0 (height) meters
*2 Approximate number of ions as measured from a point near the center of a
space of the applicable volume (0.5 meters from the oor) when operated in the
respective operating modes.
* Some speci cations may be changed for improvement purposes.
Model
Rated voltage
Applicable interior volume
*1
Operation mode
Ion density
*2
Power consumption
Outer dimensions
Weight
DC12V
Approx.
3.6
m
3
Approx. 25,000 ions/cm
3
Approx. 7,000 ions/cm
3
2.3W
Approx. 340g (Not including car adapter)
IG-BC2E
LOW
HIGH
HOW TO REPLACE
Turn the tip of the cigar plug and remove it.
1
5A glass
tube fuse
New fuse
Insert the new fuse, then
reassemble as before.
2
Be sure to replace with a 5A glass tube
fuse (commercially available).
1.3W
Cylindrical, 80 mm upper section diameter / 65 mm lower section
diameter x 150 mm height (Not including car adapter)
ACCESSORIES
Car Adapter / Operation manual