LC-24LE170I
6 – 2
1. SIGNAL ADJUSTMENT
A. PICTURE ADJUSTMENT
Confirmation of signal from generator (setting to spec level)
PAL Composite signal :0.7Vp-p ± 0.02Vp-p (pedestal to white level)
33K Component signal (60Hz) : Y level :0.7Vp-p ± 0.02Vp-p (pedestal to white level)
Pb, Pr level :0.7Vp-p :0.7Vp-p ± 0.02Vp-Com
(1) Adjustment Mode
NO.
ITEM
CONDITION
PROCEDURE
i
Adjustment Mode
Press the test key at the test remote control
(2) Component 33K 60Hz Signal Adjustment (COMP-HD)
NO.
ITEM
CONDITION
PROCEDURE
i
Setting
[Signal]
COMP 33K 60Hz
(1080i)
100% Full-field Colour
Bar
[Terminal]
COMPONENT
INPUT 2
・Feed the COMPONENT 33K 60Hz (1080i) 100% Full-field
Colour Bar signal(100% colour saturation) to COMPONENT
INPUT 2
ii
Auto Adjustment
Test Mode page 5
(COMP HD)
At the related page, move cursor to [COMP HD ADJ], press
ENTER.
[OK] appears when finished.
100% White→ ←Black