EasyManua.ls Logo

Sharp LC-70EQ10U - Page 73

Sharp LC-70EQ10U
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LC-60/70EQ10U,SQ10U/15U/17U,TQ15U,UQ17U
5 – 14
[Adjustment standard value]
Measuring instrument: [TOPCON SR-UL2] Technical measuring instrument.
Level Reference value Adjustment spec Inspection spec
Point 7 928
X=0.272
±0.0010 ±0.0020
y=0.277
Point 6 784
X=0.2755
±0.0015 ±0.0030
y=0.2720
Point 5 624
X=0.2755
±0.0020 ±0.0040
y=0.2720
Point 4 432
X=0.2755
±0.0030 ±0.0060
y=0.2720
Point 3 304
X=0.2755
±0.0035 ±0.0070
y=0.2720
Point 2 192
X=0.2755
±0.0040 ±0.0080
y=0.2720
Remarks Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment.
LC-60SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
LC-70SQ10U,15U,17U/EQ10U/TQ15U:Min 240cd/m2
Adjustment
point
Adjustment conditions Adjustment procedure

Table of Contents

Other manuals for Sharp LC-70EQ10U

Related product manuals