ELECTRICAL
SHARP
20
TRANSFER VOLTAGE SIMULATION 08-06
Item/Display
Content
Adjustment
range
Default
value
1
TC1
T1 LO CL K
Primary transfer
bias adjustment
value
K
Low speed mode
0 to 255
95
2
T1 MI CL K
Middle speed
mode
0 to 255
146
3
T1 LO CL CMY
CMY
Low speed mode
0 to 255
139
4
T1 MI CL CMY
Middle speed
mode
0 to 255
186
5
T1 LO BW K
K
Low speed mode
0 to 255
95
6
T1 MI BW K
Middle speed
mode
0 to 255
146
1
TC2
T2 PLN CL S
Secondary
transfer bias
adjustment value
Standard
paper
mode
Front surface
mode
0 to 255
103
2
T2 PLN CL D
Back surface
mode
0 to 255
96
3
T2 PLN BW S
Front surface
mode
0 to 255
90
4
T2 PLN BW D
Back surface
mode
0 to 255
83
5
T2 HEV1 CL S
Heavy
paper
mode
Front surface
mode
0 to 255
83
6
T2 HEV1 CL D
Back surface
mode
0 to 255
76
7
T2 HEV1 BW S
Front surface
mode
0 to 255
76
8
T2 HEV1 BW D
Back surface
mode
0 to 255
69
9
T2 OHP CL
OHP
0 to 255
69
10
T2 OHP BW
0 to 255
69
11
T2 ENV CL
Envelope
0 to 255
69
12
T2 ENV BW
0 to 255
69
13
T2 THIN CL
Thin paper
0 to 255
96
14
T2 THIN BW
0 to 255
90
15
T2 GLOS CL
Gloss paper
0 to 255
83
16
T2 GLOS BW
0 to 255
76
1
TC2
CLEAN
T2 MNS CLEAN
Secondary
transfer cleaning
bias adjustment
value
Cleaning mode (-)
0 to 255
59
2
T2 PLS CLEAN
Cleaning mode (+)
0 to 255
119
3
T2 COUNTER
Counter (+)
0 to 255
119
4
T2 BTWN LO
Low speed print mode (+)
0 to 255
0
5
T2 BTWN MI
Middle speed print mode (+)
0 to 255
0

Other manuals for Sharp MX-C301W