Dead machine service check
Diagnostics and troubleshooting
256
Step 1
Check the AC line for proper voltage.
Does the AC line have proper voltage?
Step 2
Use an electrical outlet that has proper voltage.
Does the problem remain?
Step 3
Check the power cord for damage, and replace if necessary.
Does the problem remain?
Step 4
Check the cable on the LVPS and on the JLVPS connector on the
controller board for proper connection.
Is the cable properly connected at both ends?
Step 5
Reconnect the cable.
Does the problem remain?
Step 6
Check the cable for continuity.
Does the cable have continuity?
Step 7
Replace the cable.
Does the problem remain?
Step 8
Measure the values of pin 4, 6, 8, and
11
to 26 of the JLVPS
connector on the controller board. See
“Controller board
connectors” on page 430
.
Are the values approximately correct?
Step 9
Replace the LVPS. See
“LVPS removal” on page 342
.