Test Simulations
20
DocumentSolutionsAfterSalesService
Main Sub Functions
24 15 Clear the counters related to the scan mode and the image send.
30 Initialize the administrator (Admin) password.
31 Initialize the service mode password.
35 Clear the toner cartridge use status data.
25 1 Check the operations of the developing section.
2 Make the initial setting of toner density when replacing developer. (Automatic
adjustment)Image process (Photoconductor/Developing)
4 Display the operation data of the toner correction
26 1 Set Yes/No of installation of the job separator.
2 Set the paper size of the paper feed tray. (When the paper size is changed, this
simulation must be executed to change the paper size in software.)
3 Set the specifications of the auditor. (Setting must be made according to the auditor
use conditions.)
5 Set the count mode of the total counter and the maintenance counter.
6 Set the specifications (paper, fixed magnification ratio, etc.) of the destination.
10 Set the trial mode of the network scanner.
18 Set Disable/Enable of the toner save mode operation.
30 Set the operation mode corresponding to the CE mark.
32 Set the special functions.
35 Set the display mode of SIM 22-4 trouble history when a same trouble occurred
repeatedly. There are two display modes: display as one trouble and display as
several series of troubles.
38 Set Continue/Stop of print when the maintenance life is reached.
50 Set functions.51Used to set the specifications of the serial port operation. (For PCI)
52 Set whether non-printed paper (insertion paper, cover paper) is counted up or not.
56 Set ON/OFF of the Life Correction.
65 Set the finisher alarm mode.
69 Set the operating conditions for toner near end.
73 Enlargement continuous shoot, A3 wide copy mode image loss (shade delete
quantity) adjustment
74 Set the OSA trial mode.
78 Set the password of the remote operation panel.
79 Set YES/NO of the pop-up display of user data delete result.
27 1 Set non-detection of communication error (U7-00) with RIC.
2 Set the sender's registration number and the HOST server telephone number.
4 Set the initial call and toner order auto send.
5 Set the machine tag No. (This function allows the host computer to check the
machine tag No.) (FSS function)
6 Set of the manual service call.
7 Set of the enable, alert callout.
9 Set the paper transport time recording YES/NO threshold value and shading gain
adjustment retry number.
10 Clear the trouble prediction history information.
11 Check the serial communication retry number and the scanner gain adjustment
retry number history.