Problem
Fan does not operate. 1. Motor does not operate.
2. Faulty connect the power connector
other.
3. Coil stator shock or lack of.
4. Bush friction.
5. Fuse deciency.
6. Temp. fuse deciency
1. Screws hold the motor cover-F.
2. Motor jam with stator.
3. Bush loose or friction.
1. Faulty gear box.
2. Link rod retaining screws too tight.
1. Hinge spring out of hinge.
2. Faulty hinge spring.
3. Hinge ass’y screw too tight.
1. Bush wear.
2. Bush axis with rust.
1. Contact switch does not touch each
2. Faulty connector lead wise.
1. Reel spring fail.
2. Spring lock slide shaft fall.
3. Replace motor or stator parts.
4. Repair or replace (Tap the axis).
5. Replace fuse.
6. Replace temp. fuse.
1. Screws rmly.
2. Repair or replace the motor.
3. Repair or replace (Tap the axis).
1. Repair or replace the motor.
2. Set correctly.
1. Set correct.
2. Replace hinge spring.
3. Set correct.
1. Replace bush and motor or
motor bush.
1. Clean contact surfaces.
2. Repair the connector.
1. Replace or repair the reel spring.
2. Replace the spring lock slide shaft.
or switch.
1.1 Repair and replace the motor.
1.2 Replace current fuse.
2. Repair.
Motor’s noise.
Fan does not oscillate.
Tilt the fan does not adjust.
Blade rotation friction.
Some switch button do not switch off.
Slide shaft does not work.
Possible Cause
Corrective Action