SHARP SERVICE MANUAL
ELECTRIC FAN
MODEL PJ-TA181
In the interests of user-safety (Required by safety
regulations in some countries) the set should be restore
to its original condition and only parts identical to those
specied should be used.
SHARP CORPORATION
TABLE OF CONTENTS
PARTS IDENTIFICATIONS AND SPECIFIC INFORMATION ...................................................
CAUTIONS FOR USE ....................................................................................................................
CLEANING AND MAINTENANCE ................................................................................................
WIRING DIAGRAM AND CIRCUIT DIAGRAM ...........................................................................
COMPONENT REPLACEMENT PROCEDURE .........................................................................
TROUBLESHOOTING ....................................................................................................................
SERVICE PARTS LIST ...................................................................................................................
Page
2 - 3
4
4
5
6-10
11
PJ-SL181

Questions and Answers

  • M
    Michael VargasJul 31, 2025
    Why is my Sharp Fan not operating?
    • A
      Adrian JohnsonJul 31, 2025
      Your Sharp Fan might not be operating due to several reasons. The motor could be faulty, requiring repair or replacement. A fuse might be deficient and needs replacement. There could be a faulty connection in the power connector or switch, which would need to be repaired. The coil stator could have a shock or be lacking, which means you should replace the motor or stator parts. Bush friction could also be the problem; in this case, repair or replace the parts, tapping the axis. Finally, a temperature fuse deficiency may exist, requiring replacement of the temperature fuse.
  • L
    ltorresAug 5, 2025
    What to do if my Sharp PJ-TA181 motor is making noise?
    • C
      Carl RodriguezAug 5, 2025
      If your Sharp Fan motor is making noise, check the screws holding the motor cover. Ensure they are firmly tightened. The motor may be jammed with the stator, which requires you to repair or replace the motor. Another cause may be loose or friction in the bush; in this case, repair or replace the parts, tapping the axis.
  • M
    mirandalaraAug 9, 2025
    Why Sharp Fan does not oscillate?
    • P
      Paul SmithAug 9, 2025
      If your Sharp Fan does not oscillate, it could be due to a faulty gear box, which may require repair or replacement of the motor. Alternatively, the link rod retaining screws might be too tight; ensure they are correctly set.
  • V
    vstanleyAug 13, 2025
    What to do if some switch button on Sharp PJ-TA181 do not switch off?
    • S
      ssmithAug 13, 2025
      If some switch buttons on your Sharp Fan do not switch off, the contact switch may not be touching each other; in this case, clean the contact surfaces. Also, there could be a faulty connector lead, which requires repairing the connector.
  • R
    robinsonericAug 17, 2025
    How to fix Sharp Fan when blade rotation has friction?
    • J
      Jared ValdezAug 17, 2025
      If your Sharp Fan's blade rotation has friction, it might be due to bush wear. Replace the bush and motor or motor bush. Another possible cause is rust on the bush axis.
  • J
    John BriggsAug 22, 2025
    Why tilt the Sharp PJ-TA181 does not adjust?
    • K
      Katrina CardenasAug 22, 2025
      If the tilt on your Sharp Fan does not adjust, the hinge spring might be out of the hinge. Set it correctly. Another cause may be a faulty hinge spring, which requires replacing the hinge spring. Also, the hinge assembly screw might be too tight; ensure it is correctly set.
  • A
    Amber HowardAug 27, 2025
    What to do if slide shaft of Sharp Fan does not work?
    • T
      Todd MurphyAug 27, 2025
      If the slide shaft on your Sharp Fan does not work, the reel spring might have failed. Replace or repair the reel spring. Another cause may be the spring lock slide shaft fall, which requires replacing the spring lock slide shaft.

Summary

Parts Identification and Specific Information

Specific Information

Details about the fan's technical specifications and measurements.

Cautions for Use

Cleaning and Maintenance

Wiring and Circuit Diagrams

Circuit Diagram

Visual representation of the fan's electrical connections and circuit layout.

Component Replacement Procedures

Remove of Grille Assembly

Step-by-step guide for disassembling and removing the grille assembly.

Remove of Hard Board

Instructions for removing the internal hard board component of the fan.

Remove of Power Cord

Procedure for safely disconnecting and removing the fan's power cord.

Remove of Piano Switch Assembly

Steps to remove the piano switch assembly from the fan.

Remove of Motor Assembly

Detailed instructions for removing the motor assembly unit.

Remove of Reel Spring

Procedure specific to PJ-SL181 for removing the reel spring.

Remove of Hinge Assembly

Steps for disassembling and removing the hinge assembly.