Initialization (Reset)/Functional Restriction Setting (FUNCTION)
You can reset the settings to the factory default settings or 
restrict operations.
To initialize the APPLICATION mode settings, select “System 
Settings” – “Backup & reset” – “Factory data reset” on the 
CONTENT MENU screen of APPLICATION mode.
1.  Press the FUNCTION button, and then press the MENU 
button within 10 seconds.
▲
▲▲▲▲▲▲
▲▲▲▲
▲
▲▲
OFF
ON 1
ON
ON
LED
OFF
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
APPLICATION SETTING
MONITOR
POWER BUTTON
EXTERNAL CONTROLLER INPUT
OPTION
SAVE/RESTORE SETTING VALUE
APPLICATION REBOOT
  OK:[ENTER]  END:[RETURN]
MAIN SOFTWARE UPDATE
2.  Select and set the items.
ALL RESET
Resets the settings to the factory default settings.  
Press the ENTER button, select the resetting method, 
and then press the ENTER button.
After initialization, turn the main power switch off and 
then back on.
ALL RESET1 ....Resets all the settings to the factory 
default settings.
ALL RESET2 ....Returns all settings to the factory default 
settings except for the following items: 
ID No. SET, REMOTE No., BAUD RATE
ADJUSTMENT LOCK
You can disable operations on the monitor and the 
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power 
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled. 
Disables all operations other than FUNCTION (not 
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with 
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control 
operation
MONITOR BUTTONS ... Prohibits monitor button 
operation
BOTH ............................. Prohibits remote control and 
monitor button operation
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed 
by the display. Shows messages during 
operation.
OFF ............... Hides all menus, modes and messages.
LED
Species whether to light the power LED.
TEMPERATURE ALERT
Selects the notication method for an abnormal 
temperature.
OFF ................ Do not notify about an abnormal 
temperature.
OSD & LED .... When an abnormal temperature is 
detected, the power LED ashes in red 
and green alternately and the screen 
displays a message: TEMPERATURE.
LED................. When an abnormal temperature is 
detected, the power LED ashes in red 
and green alternately.
STATUS ALERT
Selects the notication method for a hardware error.
OFF ................ Do not notify about the error.
OSD & LED .... When a hardware error is detected, the 
power LED ashes in red and the screen 
displays a message: STATUS [xxxx].
LED................. When a hardware error is detected, the 
power LED ashes in red.
APPLICATION SETTING
Set whether or not APPLICATION mode is used.
OFF .............. Do not use APPLICATION mode. The 
input mode cannot be changed to 
APPLICATION.
ON ................ Use APPLICATION mode.