Confidential
For use by Sharp authorized dealers
and distributors only.
Not for general distribution.
PN-HB851/HB751/HB651/HM851/HM751/HM651 Installation Guidelines <Rev1.0> April. 2019
6
Space requirement
Securing space at the Top/ Bottom/ Left/ Right/ Behind/
Surface of the monitor is necessary regardless of wall-
hanging or stand type installation.
Landscape /
Portrait Installation
Horizontal
Installation
(Only faceup)
Top 20.0cm 20.0cm
Bottom 5.0cm 20.0cm
Side 5.0cm 20.0cm
Behind 3.5cm 20.0cm
Surrounding
temperature
0~40℃ 0~30℃
*this figures are without outer casing.
If you install with outer casing, requirements are changed by size/location of vent
hole, whether or not fan.
The effectiveness of each measure differs depending on the
environment. Please choose the best measure for respective
environment as follow.
- Adding a cooling fan(please use the filter and clean it regularly.)
- Improve the ventilation by widening its space
- Adding a heat exchanger
Heat prevention unit
(Apiste co.)
Example of fan installation
- If the temperature is too high Electronic component’s
life time will be shortened or break down.
-If the temperature on LCD surface is too high
Monitors will break down or uniformity issue will occur
- If the temperature is too low Monitors will break down,
will not launch or monitor issue will occur.
The thermal influence
Temperature control and clearance space
conditions
- Usable temperature range
※ 1
→0℃-40℃ (Horizontal Installation:0~30℃)
- Temperature of LCD surface → Under 60℃
Please follow these requirements when setting the
monitor. Refer to them and install the monitor according
to its requirements.
※1: this range may change by requirements.
2.1 Precautions for temperature and clearance space