*1 Details of P1.12 (NORMAL STANDBY CAUSE)
When TV set is powered off due to normal use or product specification, the last cause will be recorded.
The code, character string and description for the standby cause are below.
If you power off by remote, the cause will not be recorded.
*2 Details of P1.13 (ERROR STANDBY CAUSE)
When TV set is powered off due to any anomaly detection, the past 5 causes will be recorded.
You can confirm the time those causes occurred and character string in the adjustment process mode menu. (Page 28/29)
The time is accumulated total after TV set is powered on, and the value corresponds to “Center Acutime” in the adjustment process mode menu.
The code, character string and description for the standby cause are below.
If no error has occurred, the code is 0 and the character string is “NO RECORD”.
Monitor ERR STBY table
Outline: Communication/Power failure detected by the monitor microcomputer is stored on EEPROM, and the last 4 abnormal states can be
confirmed in the process mode A.
Location: Page 1 of the process mode A: MONITOR ERR CAUSE “0” if there is no error. It is cleared to 0 on the last page of the process mode A.
Code Character string Description
2 NO_OPERT No operation off
3 NO_SIGNA No signal off
6 SLEEP_TM Off timer
8 OFF_232C Command from RS232C
Code Character string Description
1A E_MONITR Monitor trouble detected
1B E_CVICBT Driver boot error
22 E_TCNERR Software abnormality of LCD controller
48 E_MRESET Failure of resetting menu settings (Initial Setup - Reset)
50 E_TCNF_S T-CON FPGA status error
54 E_TCON_E T-CON hung-up
Display (HEX) Display (DEC) Error description
02 2 Start-up communication error 2 Initial communication from the main CPU is not received.
03 3 Start-up communication error 3 Only the initial communication is received.
04 4 Start-up communication error 4 Until panel information request reception
05 5 Start-up communication error 5 Until initialization completion reception
06 6 Start-up communication error 6 Until version notification transmission
07 7 Start-up communication error 7 Until start-up information notification transmission
08 8 Start-up communication error 8 Until start-up information response reception
09 9 Start-up communication error 9 Until time-out setting reception
0A 10 Communication error A REQ time-out
0B 11 Communication error B Restart time-out during the beginning of time acquisition start-up
0C 12 Communication error C Ending sequence time-out
0D 13 Communication error D Preset start-up time-out during completion
0E 14 Communication error E download, start-up time-out
0F 15 Communication error F Time acquisition time-out
11 17 Communication error H Regular communication time-out
16 22 Panel-related error Lamp failure
1A 26 Other error 2 Monitor temperature failure
1E 30 Power supply error 2 PS_ON (DET_13V) failure
1F 31 Power supply error 3 D_POW (DET_D3V3) failure
21 33 Power supply error 5 Panel power failure
23 35 Other error 3 Error standby request from the main CPU