PRO-60/70X5FD
6 – 1
PRO60X5FD
Service Manual
CHAPTER 6. TROUBLESHOOTING TABLE
[1] Failure diagnosis by LED in front of cabinet
[2] LED flashing specification at the time of an error (Power LED used)
1. Display method
Refer to Tables 1 and 2.
Since only one power LED is used, slow flashing and fast flashing are combined.
The Start from the detail display. (No outline display)
After recovering from an error, if the same error cannot be generated again, refer to MONITOR ERR CAUSE on the process screen.
During version upgrade or when completing it, the flashing cycle changes.
2. LED flashing method
Error flashing
<Detail display example>
Flashing during Verup
Flashing when completing Verup
No
Yes
No
Yes
No
Yes
Is the Center Icon flashing?
START
Is the Center Icon lighting
When AC plug on?
Is the Backlight lighting?
Check "[2] LED flashing specification at the time of an error (Center icon LED used)".
Check Power-Unit and AC-cable.
Check "LED Backlight does not turn on.".
Check "Picture does not display.".
Power LED
1600ms
300ms
100ms
400ms
400ms
1600ms
Power LED
500ms
500ms
Power LED
2000ms
2000ms