R-3A54 
R-3E54 
1. 
Precautions  for  Handing  Electronic 
Components 
This  unit  uses  CMOS  LSI  in  the  integral  part  of  the 
circuits.  When  handing  these  parts,  the  following 
precautions  should  be  strictly  followed. 
CMOS  LSI  have  extremely  high  impedance  at  its 
input  and  output  terminals.  For  this  reason,  it  is 
easily  influenced  by  the  surrounding  high  voltage 
power  source,  static  electricity  charged  in  clothes, 
etc,and  sometimes  it  is  not  fully  protected  by  the 
built-in  protection  circuit. 
In  order  to  protect  CMOS  LSI. 
1)  When  storing  and  transporting,  thoroughly 
wrap  them  in  aluminum  foil. 
Also  wrap  PW  boards  containing  them  in 
aluminium  foil. 
2)  When  soldering,  ground  the  technician  as 
shown  in  the  figure  and  use  grounded 
soldering  iron  and  work  table. 
. . 
J 
epprox.  1MR 
Ift?Y 
7h 
2.  Shapes  of  Electronic  Components 
Transistor 
DTAI  14ES 
DTAI  43 ES 
DTC143ES 
DTDl43ES 
3.  Servicing  of  Touch  Control  Panel 
We  describe  the  procedures  to  permit  servicing  the 
touch  control  panel  of  the  microwave  oven  and  the 
cautions  you  must  consider  when  doing  so. 
To  carry  the  servicing,  power  supply  to  the  touch 
control  panel  is available  either  from  the  power  line 
of  the  oven  proper  itself  of  from  an  external  power 
SERVDCING 
source. 
(I)  Servicing  the  touch  control  panel  with 
power  supply  from  the  oven  proper: 
CAUTION: 
THE  HIGH  VOLTAGE  TRANSFORMER  OF 
THE  MICROWAVE  OVEN  IS  STILL  ALIVE 
TO  GIVE  YOU  DANGER  DURING  SER- 
VICING. 
Therefore,  when  checking  the  performance  of 
the  touch  control  panel,put  the  outer  cabinet 
on  the  oven  proper  to  keep  from  touching  the 
high  voltage  transformer,  or  unplug  the  primary 
terminal  (connector)  of  the  high  voltage  trans- 
former  to  turn  it  off;  and  the  end  of  such  con- 
nector  shall  be  insulated  with  an  insulating 
tape.  After  servicing,  be  sure  to  replace  the 
leads  to  their  original  locations. 
A.  On  some  models,  the  power  supply  cord  be- 
tween  the  touch  control  panel  and  the  oven 
proper  is  so  short  that  they  can’t  be  separated 
from  each  other. 
For  those  models,  therefore,  check  and  repair 
all  the  controls  (with  the  sensor-related  ones 
included)  of  the  touch  control  panel  while 
keeping  it  in  contact  with  the  oven  proper. 
B  On  some  models,  on  the  other  hand,  the  power 
supply  cord  between  the  touch  control  panel 
and  the  oven  proper  is  so  long  that  they  may 
be  separated  from  each  other.  For  those  mod- 
els,  therefore,  it  is  allowed  to  check  and  repair 
the  controls  of  the  touch  control  panel  while 
keeping  it  apart  from  the  oven  proper;in  this 
case  you  must  short  both  ends  of  the  stop 
switch  (on  PWB)  of  the  touch  control  panel 
with  a  jumper,  which  brings  about  an  opera- 
tional  state  that  is  equivalent  to  that  with  the 
oven  door  being  closed. 
As  to  the  sensor-related  controls  of  the  touch 
control  panel,  their  checking  is  allowed  if  the 
dummy  resistor(s)  whose  resistance  is  equal  to 
that  of  those  controls  is  used. 
(2)  Servicing  the  touch  control  panel  with 
power  supply  from  an  external  power 
source: 
Disconnect  the  touch  control  panel  completely 
from  the  oven  proper,and  short  both  ends  of 
the  stop  switch  (on  PWB)  of  the  touch  control 
panei,which  brings  about  an  operational  state 
that  is  equivalent  with  the  oven  door  being 
closed.  And  connect  an  external  power  source 
to  the  power  input  terminal  of  the  touch  control 
panel,  and  then  it  is allowed  to  check  and  repair 
the  controls  of  the  touch  control  panel;as  in  the 
case  of  (1)  - B  above, 
it  is  here  also  possible  to 
check  the  sensor-related  controls  of  the  touch 
control  panel  by  using  the  dummy  resistor(s). 
4.  Servicing  Tools 
Tools  required  when  servicing  the  touch  control 
panel  assembly. 
1)  Soldering  iron:  30W  (To  prevent  leaking  cur- 
rent,  it  is recommended  to  use  a soldering  iron  with 
a grounding  terminal.) 
2)  Oscilloscope: 
Single  beam,  frequency  range: 
DC  -  1 OMHz  type  or  more  ad- 
vanced  model. 
3)  Others: 
Hand  tools 
5.  Other  Precautions 
1)  Before  turning  on  the  power  source  of  the 
control  unit,  remove  the  aluminum  foil  applied 
for  preventing  static  electricity. 
2)  Connect  the  connectors  of  the  indicator  and 
key  units  to  the  control  unit  taking  care  that  the 
lead  wires  are  not  twisted. 
3)  After  aluminum  foil  is  removed,  take  extra  care 
that  abnormal  voltage  due  to  static  electricity 
etc.  is  not  applied  to  the  input  or  output  termi- 
nals. 
4)  Attach  connectors,  electrolytic  capacitors,  etc. 
to  PWB,  taking  care  that  ail  connections  are 
tight. 
5)  Be  sure  to  use  specified  components  where 
high  precision  is  required. 
21