6-4.  After  approximately  3 seconds,  cooking  operation  turns  off,  an  audible  signal  will  sound.  and 
the  display  will  then  revert  to the  time  of day. 
If the  above  is  not  the  case,  the  control  unit  is probably  defective. 
If the  above  is proper,  the  AH  sensor  is probably  defective. 
Rl,  R2:  22 ilil%  1,2w 
R3:lOk  iZ t  5O& 1,4W 
R4:  IM  <Iz~?/o  l14W 
To  connector  (F) 
on  Control  Unit. 
CONNECTOR 
Figure  A.  Sensor  Dummy  Resistor  Circuit 
Iger 
NC 
NO 
P  WElGHT  SENSOR  ASSEMBLY  AND  lC3(MEMORY)  TEST. 
After  replacing  the  weight  sensor  or  iC3.  carry  out  the  following  orocedure  :r, order  13 saiibrare  ir, 
weight  sensor.  If the  weight  sensor  is not  recalibrate,  the  food  may  oe  over  or Grde-  ..xcw:. 
The  following  procedure  should  be  carried  out  garth imicrowave  over  rn a  ftQ  as<~r;l~ler:  conZ;t  c’- 
(with  outer  case  fitted}. 
1.  Place  the  turnrable  on  the  turntable  support  plate  correctly,  and  close  the  door 
2.  Plug  the  oven  into  a power  point.  (“88:88”  will  appear  on  the  display.) 
3.  After  3 seconds  or  more.  Press  the  STOP/CLEAR  pad.  (Display  shows  ”  0”  .Gth  sound  .c;: 
buzzer.) 
4.  Press  the  AUTO  START’CLOCK  pad.  (Display  shows  ”  0”  with  sound  of  buzzer.) 
5. 
Press  the  GRILL  pad.  (Display  shows  ”  O”.) 
6.  Press  the  POWER  LEVEL  pad.  (Display  shows  ”  O”.) 
7.  Press  the  INSTANT  COOK/START  pad.  (Display  shows  ” TEST”  with  sound  of  buzzer.! 
8.  Press  the  “4”  of number  pads.  (Display  shows  ” DISH”  with  sound  of buzzer.  and  tuntable  and  oven 
lamps  come  on.) 
9.  After  13 seconds,  make  sure  that  the  display  shows  “25000  - 35000”  with  sound  of  buzzer. 
If display  shows  less  than  25000  or  more  than  35000,  weight  sensor  is  defect. 
10.  Place  the  weight  2  Kg + 209  (water  load  2  Kg  + 209)  on  the  turntable. 
11.  Press  the  “6”  of  number  pads.  (Display  shows  ” 
DISH”  with  sound  of  buzzer,  and  turntable  and 
oven  lamps  come  on.) 
12.  After  13 seconds,  make  sure  that  the  display  shows  “02300  - 02800”  with  sound  of  buzzer. 
If display  shows  less  than  02300  or  more  than  02800,  weight  sensor  is  defect. 
13.  Disconnect  the  oven  from  power  supply,  and  repeat  above  procedure  items  1 to  7 
14.  Press  the  “7”  of  number  pads,  and  make  sure  that  the  display  shows  "02300 -02800". 
If display  shows  less  than  02300  or  more  than  02800,  IC3  is  defect. 
MONITOR  RESISTOR  TEST 
CARRY  OUT  aCHECKS. 
Disconnect  the  leads  from  the  monitor  resist.  Using  an  ohmmeter  and  set  on  a  low  range.  Check 
between  the  terminals  of  the  monitor  resistor. 
The  resistance  of  monitor  resistor  is approx.  0.8  ohms. 
If incorrect  readings  are  obtained,  replace  the  monitor  resistor. 
CARRY  OUT  4R  CHECKS. 