5-14
VL-H870U
VL-H875U
VL-H890U
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
VL-H860S/H/VL-H870S
VL-H890S/VL-H94E
VL-H96E/VL-H960E
5-4-2-1. Checking the power supply voltage
Measuring terminal: CAM 4.9V
CAM 2.8V
CAM 3.1V
CAM 15V
CAM -7V
LENS 5V
Measuring instrument: Digital voltmeter
5-4-2-3. Adjustment of Camera signal
Before starting these adjustment, auto focus adjustment must be finished.
Set up the camera signal adjustment mode (Write 00 to the address 1FE)
1. Sync level adjustment
Measuring instrument Oscilloscope
Subject Anything
Tape
Test point VIDEO OUT (Terminated in 75)
Adjustment address 1F8
Adjustment level 300mVp-p
1) Connect the oscilloscope to the VIDEO-OUT. Adjust the sync
level to 300mVp-p.
1H
Video
SYNC
300mVp-p
5-4-2-2. Auto focus adjustment
Measuring instrument None
Subject
Tape
Test point None
Adjustment address 1FF
Adjustment level 09, 0A, 0B
Basic iris adjustment
1) Set up the auto focus adjustment mode. (Write 01 to the address 1FE)
2) Write the adjustment data 09, 0A and 0B one after the other to the address 1FF, the adjustment are as above.
DATA Adjustment
09 Hall offset
0A Iris offset
0B Iris close
Lens adjustment
Measuring instrument None
Subject More than 50 m away
Tape
Test point None
Adjustment address 1FF
Adjustment level 11, 12, 06, 08, 0D
DATA Adjustment
11 Voltage adjustment
12 Optical wide-end adjustment
06 Wide-end focus position adjustment
08 Tele-end focus position adjustment
0D Zoom tracking adjustment
1) Set up the auto focus adjustment mode.
(This is unnecessary after the above basic iris adjustment has been made.)
2) Write the adjustment data 11, 12, 06, 08 and 0D one after the other to the address 1FF. The adjustments are as above.
Write FF to the address 1FE to exit the auto focus adjustment mode.
700mVp-p
Measuring instrument Oscilloscope
Subject Gray scale
Tape
Test point VIDEO-OUT
Adjustment address 1FC
Adjustment level 700mVp-p
1) Shoot the gray scale in the standard way. Observe the VIDEO-OUT signal on the oscilloscope screen and rewrite the data of
address 1FC to get an amplitude of 700mVp-p as shown above.
2. Iris AE adjustment
3. Black balance , AF noise level adjustment
Measuring instrument None
Subject Anything
Tape
Test point None
Adjustment address 1FF
Adjustment level 01
1) Preparation : Write FF to address 19C, 19D, 19E, 19F, 1AO,
1AI.
2) Write the data 01 to the address 1FF.
The following adjustments are automatically
carried on ; 1 Black balance adjustment
2 AF noise level adjustment
at AGC Gain Min , AGC Gain Max and Gain up.
3) Data processing after adjusting the noise level calculation
formula (Round off fractions).