L-PDl U
1 O-2. Camera Section Adjustments
1 O-2-1. Camera section service
(1)Camera adjustment is performed after the set has been completed.
(2)Subjects, measuring instruments and jigs needed for camera section service and adjustments
l Gray scale chart
l Illumination meter
l Remote control unit for servicing
l White chart
l Colour temperature meter
l Colour bar chart
l Colour temperature conversion filter HOYA “LB-1 65”
l Oscilloscope
l Colour video monitor
l Digital voltmeter
l Video output cable
l Vector scope
l Halogen lamp: 2 PCS. l AC adapter
l Frequency counter
l Extension cables
10-2-2. List of camera jigs and tools
Note: N indicates a new jig.
Colour temperature
conversion filter JiGHOYA-LB165
PC plate connector drawer
JiGTH-SSI 0
7 Remote control until for servicing
RRMCG0033TASA BT
b-
L- by
_- b-
Q
--
10-2-3. Adjusting the camera unit
(l)Preparations for adjustments and items to be checked
1) Set up the light box so that the entire pattern is evenly lit. Set the colour temperature to 3200OK.
2) Use test patterns that are not dirty nor discoloured.
3) If the electrical circuitry gets in trouble, be sure to pinpoint the trouble spot with a measuring instrument and repair
or replace the defective part.
(2)Remote control for servicing RRMCG0033TASA
To adjust the camera section of this machine, the remote control for servicing (RRMCG0033TASA) is used. The
adjustment is made in such a manner that the remote control writes necessary data by way of the microprocessor to
the specific addresses on the E2PROM (IC502 and the ROM on the lens unit).
1) To adjust the camera:
Press the “CONTINUE” key first and then the “CAM ADJ” key.
This will show
CAM ADJ
. . . . . ., . . . . . ., . . . . . ., . . . .,
. ::::::
i: :: :::
:
. . . . . . . : . . . . . i . . . . . i . . . . . i
on the LCD screen, thereby having the camera unit ready for the adjustments.