dL-PDI U
2) Shifting to the normal operation mode
Set the data for the address “05FE” to ~.1_j~.‘.~_j FF”.
9
This makes the screen fade temporarily in white and shifts to the normal operation mode.
a
Press the “CONTINUE” key, and the “CAM ADJ” display goes out of the screen, enabling the normal operation.
(4)Camera signal system adjustment mode
In the camera signal system adjustment mode, the automatic white balance is disabled to allow for the adjustment of
the camera unit. At this time, the white balance mode is fixed at the INDOORS mode and the focus mode is switched
to the manual focus mode.
1)
2)
Shifting to the camera signal system adjustment mode
.a..... .......
Set the data for the address “OOBO” to i._../ i..../ 00”.
a
This shifts the mode to the auto-focus function adjustment mode.
*When this adjustment mode has been shifted to, make the adjustment according to (5) Camera unit adjustment
procedure.
Shifting to the normal operation mode
Set the data for the address "OOBO" to ~_~.~$~~_~~ FF".
0
This shifts the mode to the normal operation mode.
e
Press the “CONTINUE” key, and the “CAM ADJ” display goes out of the screen, enabling the normal operation.
(5)Camera unit adjustment procedure
1. Auto focus adjustment
1
2. Iris basic adjustment
3. Black balance adjustment/A/F noise adjustment
4. Iris AE adjustment
I
5. White balance coarse adjustment
I
6. Colour gain coarse adjustment
w
7. White balance adjustment.
8. Colour gain adjustment
9. Auto white balance adjustment
* The above 1. Auto-focus function adjustment and 2. iris basic adjustment are performed in the auto-focus function
adjustment mode, whereas the other adjustments are made in the camera signal system adjustment mode.
* After completing the auto-focus adjustment mode, set the camera signal system adjustment mode. (Take care that the
adjustment mode transfer address is different.)
(6)Gyro unit replacement method
I) Replacing the lens without replacing the gyro sensor unit
The gyro adjustment data has been written in the E2PROM of lens. Write the data of address 456 to 459.
2) Replacing the gyro sensor
After replacing the specified gyro sensor, write the following
Address Data
456 01
Replacing S2 (RSNSG0004CEOl)
457 EO
Replacing S2 (RSNSG0004CEOl)
458 03
Replacing Sl (RSNSG0005CEOl)
data in the address 456 to-459.