VL-PDl U
EE output
Address:
“0018” INDOOR W/BR
“001 A” INDOOR W/BR
Measuring instrument:
Vector scope
Object:
G rey scale
Data variation width:
“0000” to “03FF”
(1) Colour gain adjustment is performed repeatedly.
Address:
“012B” CGIN RYG
“012D” CGIN BYG
“0128” CMAT RYG
“0126” CMAT BYG
Measuring instrument:
Vector scope
Object:
Waveform monitor colour bar
chart
Data variation width:
“0000” to “OOFF”
Red amplitude
Blue amplitude
Adjustment address
1.60 k 0.05 time (burst ratio)
: “012B”
1 .I 5 + 0.05 time (burst ratio)
: “012D”
103O + I”
n “0128” .
344” + 2”
= “0126” .
(9)Auto white balance adjustment
l Measurement terminal:
EE output
l Address:
“006A” OUTDOOR R
“006C” OUTDOOR B
l Measuring instrument:
Vector scope
l Object:
G rey scale
l Data variation width:
“0000” to “03FF”
(l)The colour temperature conversion filter (LB1 65) is mounted in front of lens.
(2) Indication of vector scope is observed in the grey scale standard record state,
and an adjustment is made so that the luminous dots are located in the
following positions:
R-Y 0 + 5% (burst ratio)
B-Y 0 + 5% (burst ratio)
After completion of adjustment set the regular operation mode (the data ..’ _: .I,,: FF” is written in the address “OOBO”.)
1 o-22