Item
(7) White
balance adjustment
l
Measurement
terminal:
EE
output
l
Address:
“OOOC”
INDOOR W/BR
“OOOE” INDOOR W/BR
l
Measuring
instrument:
Vector scope
l
Object:
Grey scale
l
Data variation width:
“0000” to “03FF”
Adjustment
method
(1)
White balance
adjustment is performed repeatedly.
(8)
Color gain
adjustment
(1)
Color gain adjustment is performed
repeatedly.
l
Measurement
terminal:
EE output
l
Address:
“0166” CGIN
RYG
“0168” CGIN BYG
“0164” CMAT
RYG
“0162” CMAT BYG
l
Measuring instrument:
Vector scope
l
Object:
Waveform monitor color bar chart
l
Data variation width:
“0000” to “OOFF”
Adjustment address
Red amplitude
1.45 + 0.05 time (burst ratio)
: “0166”
Blue amplitude
1.15 k 0.05 time (burst ratio)
:
“0168”
Red phase
100” f 1”
: “0164”
Blue phase
347” f 2”
:
“0162”
(9)Auto white balance adjustment
l
Measurement terminal:
EE output
l
Address:
“OOAO” OUTDOOR R
“OOA2” OUTDOOR B
l
Measuring instrument:
Vector scope
l
Object:
Grey scale
l
Data variation width:
“0000” to “03FF”
(1) The color temperature conversion filter (LB1 65) is mounted in front of
lens.
(2) Indication of vector
scope is observed in the grey scale standard record state, and
an adjustment is made so that the luminous dots are located in the
following
VL-SD2OU
After completion of adjustment set the regular operation mode (the data
FF” is
wrltten In the address “uuuu”.)
10-17