XEA147BK and XEA147WH Frequently Asked Questions Page 11 of 21
How do I stop the Electronic Journal near full error symbol from dispalying?
7. Set the mode key to the Z/PGM position
8. Enter:
#/TM/ST 6 8 _/RCPT/SW 1 0 1 _0_ 0 0 1 0 #/TM/ST TL/AT/NS
This will cause the near full symbol for the Electronic Journal (EJ), not to display. The EJ near full
warning symbol is a displayed right below the 7
th
and 8
th
places on the display. If this warning is
disabled records in the EJ will be deleted on a first in first out (FIFO) basis. The EJ has a 3000 line
capacity.
How do I give a department a descriptive name?
1. Set the mode key to the Z/PGM position
2. Enter: #/TM/ST -1- -0- -1- _/RCPT/SW_ DEPT KEY enter characters
#/TM/ST TL/AT/NS
For example to enter ‘SNACKS’ as the department’s description
Enter: : #/TM/ST -1- -0- -1- _/RCPT/SW_ -8- 2
6
-3- 2
6
-0- 1
5
-2- 1
5
-0- 2
6
-8- 2
6
#/TM/ST TL/AT/NS
You can enter up to 12 characters with the function and department keys. You will see the
letters of the Alphabet that a key covers in the bottom right hand corner of the key.
You can also enter text using 3 digit codes. Please refer to the full instruction manual (pages 43 -44)
for details. The character table for using the department and function keys is shown on the next page.