D1000~
D2299
Corresponding to the value of P.0~P.1299
Only P parameter can be operated. The
number of D-1000 is the P parameter
number. M8030 decides whether the
setting of P parameter is saved after
power-off. (Note 2, 3)
R/W
Note: 1. HDI terminal can only be used by PLC when M8060 and M8061 are referenced by PLC program and
PLC is valid.
2. Whether the value written to the parameter through D1000~D2299 is saved after power-off depends on the
value of M8030. M8030=0, save when power off, M8030=1, not save when power off. The operation on the
parameter D register is equivalent to the operation on the parameter.
3. D1996~D1999 corresponding to P.996~P.999 are reserved.
4. The value read by D8153 is 0.