X0 is ON, the number in D0 is subtracted from the data in D10, and the difference is stored in D20. If the difference
obtained is zero, M8020 will be set to 1.
X
Y
M
K
T
C
D
S1
O
O
O
O
S2
O
O
O
O
D
O
O
O
Flag bit: None.
S1
: The multiplicand.
S2
: Multiplier.
D
: Product.
Store the product obtained by multiplying
S1
and
S2
in
D
. The data involved in the operation are all
unsigned 16-bit binary numbers.
X0 ON, the data in D0 is multiplied by the data in D10, and the product is sent to D20 for storage.
X
Y
M
K
T
C
D
S1
O
O
O
O
S2
O
O
O
O
D
O
O
O
Flag bit: M8023 0: The divisor is not 0.
1: The divisor is 0.
X0
SUB D0 D10 D20
X0
MUL D0 D10 D20