Shimadzu AUX120 User Manual

Shimadzu AUX120
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Presented By
Dallas HoustonAustinFt Worth
NicolScales.com
800.225.8181
Contact Us
Nicol Scales & Measurement is an ISO Accredited Calibration
Company that has provided calibration, repair and sales of all types
of weighing and measurement products since 1931.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shimadzu AUX120 and is the answer not in the manual?

Shimadzu AUX120 Specifications

General IconGeneral
Maximum Capacity120 g
Readability0.1 mg
Pan SizeØ 80 mm
InterfaceRS-232C
Power SupplyAC adapter
Operating Temperature5°C to 40°C
Repeatability±0.1 mg
Linearity±0.2 mg
DisplayLCD
CalibrationAutomatic

Summary

2. Component Names and Functions

2.1 Main Components

Identifies and describes the primary physical parts of the analytical balance, including the weighing chamber and display.

2.2 Key Panel and Operation

Details the function of each key on the balance and their operational use during measurement and menu navigation.

4. Installation

4.1 Installation Site

Provides guidance on selecting an appropriate, safe, and stable location for balance installation.

4.2 Unpacking and Delivery Inspection

Outlines the procedure for checking the balance for damage and verifying contents after delivery.

4.3 Installation

Details the step-by-step process for physically setting up the balance, including leveling.

4.4 Turning On the Power

Explains how to connect the power and the initial startup sequence, including self-check and calibration.

4.5 Span Calibration

Describes the critical procedure for calibrating the balance sensitivity after installation for accuracy.

5. Basic Operation

5.1 Weighing

Guides the user through the fundamental steps for performing a weighing operation safely and accurately.

6. WindowsDirect Function

6.2 WindowsDirect Settings

Covers the setup and operations for the WindowsDirect function, including connection and PC configuration.

6.3 Troubleshooting WindowsDirect Communication

Provides solutions for common issues encountered with the WindowsDirect communication function.

10. Calibration

10.1 What is calibration?

Explains the purpose and importance of calibration for ensuring accurate measurements.

10.1.1 The Necessity of Calibration

Details conditions requiring calibration, such as temperature changes or site relocation.

10.1.2 Types of Calibration

Outlines the different calibration methods available for the balance models, including internal and external weights.

10.2 Executing Calibration

Provides step-by-step instructions for performing various calibration procedures.

10.3 Calibration Settings

Explains how to select and configure different calibration methods and options for optimal performance.

11. Environment Settings

13. Application Functions

14. Communication with Peripheral Devices

14.3 Communication Settings

Details how to configure communication parameters like baud rate, parity, and data format.

15. Maintenance and Transport

16. Troubleshooting

16.1 Error Code Displays

Lists common error codes displayed by the balance and their corresponding countermeasures.

16.2 Troubleshooting

Offers solutions for general operational issues and symptoms encountered with the balance.