EasyManua.ls Logo

Shimadzu UW820S - User Manual

Shimadzu UW820S
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
M054-E117D
Read These Pages Before Installation
Electronic Balance
Instruction Manual
UW series
UX series
READ AND UNDERSTAND THIS MANUAL BEFORE
OPERATION. SAVE THIS MANUAL.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Shimadzu UW820S and is the answer not in the manual?

Summary

Electronic Balance Instruction Manual

UW;UX Series Balances

Identifies the specific balance series covered in the manual.

Safety Precautions

Operational Safety Warnings

Highlights potential hazards and necessary precautions for safe operation.

Introduction

Key Panel and Operation

Key Functions During Operation

Explains the function of each key during weighing and menu selection.

Balance Display Information

Installation Guide

Choosing the Installation Site

Guides on selecting a suitable and safe location for balance installation.

Unpacking and Inspection

Balance Installation Procedure

Installation Safety Warnings

Provides critical safety warnings for handling the balance during installation.

Leveling the Balance

Adjusting Balance Level

Details the step-by-step procedure for leveling the balance using its adjustable feet.

Powering On the Balance

Power Connection Notes

Provides guidance on connecting the AC adapter and optional battery pack.

Span Calibration (UW Series)

Using Built-in Weight for Calibration

Step-by-step instructions for span calibration using the balance's internal weight.

Span Calibration (UX Series)

Using External Weights for Calibration

Step-by-step instructions for span calibration using external weights.

Basic Weighing Operation

WindowsDirect Setup

Configuring the Balance for WindowsDirect

Details the steps to configure the balance for WindowsDirect communication.

WindowsDirect Cable and Computer Setup

Computer Accessibility Options Configuration

Guides on configuring computer accessibility options for WindowsDirect.

Serial Key Settings

Serial Port and Baud Rate Configuration

Configuration window for serial port and baud rate settings.

Starting and Checking WindowsDirect

WindowsDirect Startup Timing Note

Important note on balance power-on timing relative to Windows startup.

Troubleshooting WindowsDirect Function

Addressing WindowsDirect Non-Operation

Troubleshooting steps for when WindowsDirect fails to operate.

WindowsDirect Intermittent Malfunctions

Troubleshooting Intermittent Issues

Addresses intermittent malfunctions and related notes for the WindowsDirect function.

Menu Item Selection Overview

Menu Item Selection Procedure

Navigating the Balance Menu System

Details the procedure for navigating and selecting menu items on the balance.

Setting Numeric Values

Setting Decimal Points for Measurements

Details on setting decimal points for specific measurement types.

Menu Lock Function

Calibration Overview

Understanding Calibration Requirements

Explains why and when balance calibration is required.

Calibration Execution

Performing Span Calibration (Built-in Weight)

Step-by-step instructions for span calibration using the balance's internal weight.

Calibration Check (UW Series)

Checking Calibration with Built-in Weight

Guides on performing a calibration check using the built-in weight.

Span Calibration with External Weights

Changing Calibration Weight Value

Procedure to modify the calibration weight value used for external calibration.

Calibration Check with External Weights

Modifying Calibration Weight for Checks

Procedure to change the calibration weight for checks using external weights.

Calibration Settings

Selecting Calibration Type

Guides on selecting the desired type of calibration execution.

Automatic Calibration Modes (UW Series)

PCAL Calibration (Built-in Weight)

PCAL Procedure and Password Protection

Explains the PCAL procedure for calibrating built-in weights and its password protection.

PCAL Password Setting

Enhancing Productivity: Checkweighing

Checkweighing Display Types

Target Mode Operation

Piece Counting (PCS) Function

Auto Print Functionality

Application Functions: Specific Gravity

Application Functions: Liquid Density

Application Functions: Peak Hold

Application Functions: Interval Timer

Application Functions: Auto-Memory and Zeroing

Application Functions: Animal Weighing

Connecting Peripheral Instruments

Connecting to Personal Computer (RS-232 C)

Data Formatting for Communication

Using Command Codes for Communication

Command Codes Reference

Command Categories

Command Codes for Values and Settings

Special Function Commands

Multi-Connection Mode Setup

Multi-Connection Command Codes and Data Format

Multi-Connection Mode Restrictions

Communication Settings Overview

Communication Format and Speed Settings

Delimiter Settings for Communication

Maintenance and Transportation

Troubleshooting: General Display Messages

Understanding General Balance Display Messages

Lists and explains general display messages that appear on the balance.

Troubleshooting: Error Displays

Error Displays and Their Countermeasures

Lists error displays, their descriptions, and recommended countermeasures.

Appendix: Menu Map Groups

Appendix: Menu Map Groups

Menu Map Overview

Menu Group 1: Calibration and PSC Settings

Details the menu structure for calibration execution and PSC function.

Key Panel and Operation Summary

Key Functions Overview

Summarizes the functions of the balance keys for operation.

Summary

Electronic Balance Instruction Manual

UW;UX Series Balances

Identifies the specific balance series covered in the manual.

Safety Precautions

Operational Safety Warnings

Highlights potential hazards and necessary precautions for safe operation.

Introduction

Key Panel and Operation

Key Functions During Operation

Explains the function of each key during weighing and menu selection.

Balance Display Information

Installation Guide

Choosing the Installation Site

Guides on selecting a suitable and safe location for balance installation.

Unpacking and Inspection

Balance Installation Procedure

Installation Safety Warnings

Provides critical safety warnings for handling the balance during installation.

Leveling the Balance

Adjusting Balance Level

Details the step-by-step procedure for leveling the balance using its adjustable feet.

Powering On the Balance

Power Connection Notes

Provides guidance on connecting the AC adapter and optional battery pack.

Span Calibration (UW Series)

Using Built-in Weight for Calibration

Step-by-step instructions for span calibration using the balance's internal weight.

Span Calibration (UX Series)

Using External Weights for Calibration

Step-by-step instructions for span calibration using external weights.

Basic Weighing Operation

WindowsDirect Setup

Configuring the Balance for WindowsDirect

Details the steps to configure the balance for WindowsDirect communication.

WindowsDirect Cable and Computer Setup

Computer Accessibility Options Configuration

Guides on configuring computer accessibility options for WindowsDirect.

Serial Key Settings

Serial Port and Baud Rate Configuration

Configuration window for serial port and baud rate settings.

Starting and Checking WindowsDirect

WindowsDirect Startup Timing Note

Important note on balance power-on timing relative to Windows startup.

Troubleshooting WindowsDirect Function

Addressing WindowsDirect Non-Operation

Troubleshooting steps for when WindowsDirect fails to operate.

WindowsDirect Intermittent Malfunctions

Troubleshooting Intermittent Issues

Addresses intermittent malfunctions and related notes for the WindowsDirect function.

Menu Item Selection Overview

Menu Item Selection Procedure

Navigating the Balance Menu System

Details the procedure for navigating and selecting menu items on the balance.

Setting Numeric Values

Setting Decimal Points for Measurements

Details on setting decimal points for specific measurement types.

Menu Lock Function

Calibration Overview

Understanding Calibration Requirements

Explains why and when balance calibration is required.

Calibration Execution

Performing Span Calibration (Built-in Weight)

Step-by-step instructions for span calibration using the balance's internal weight.

Calibration Check (UW Series)

Checking Calibration with Built-in Weight

Guides on performing a calibration check using the built-in weight.

Span Calibration with External Weights

Changing Calibration Weight Value

Procedure to modify the calibration weight value used for external calibration.

Calibration Check with External Weights

Modifying Calibration Weight for Checks

Procedure to change the calibration weight for checks using external weights.

Calibration Settings

Selecting Calibration Type

Guides on selecting the desired type of calibration execution.

Automatic Calibration Modes (UW Series)

PCAL Calibration (Built-in Weight)

PCAL Procedure and Password Protection

Explains the PCAL procedure for calibrating built-in weights and its password protection.

PCAL Password Setting

Enhancing Productivity: Checkweighing

Checkweighing Display Types

Target Mode Operation

Piece Counting (PCS) Function

Auto Print Functionality

Application Functions: Specific Gravity

Application Functions: Liquid Density

Application Functions: Peak Hold

Application Functions: Interval Timer

Application Functions: Auto-Memory and Zeroing

Application Functions: Animal Weighing

Connecting Peripheral Instruments

Connecting to Personal Computer (RS-232 C)

Data Formatting for Communication

Using Command Codes for Communication

Command Codes Reference

Command Categories

Command Codes for Values and Settings

Special Function Commands

Multi-Connection Mode Setup

Multi-Connection Command Codes and Data Format

Multi-Connection Mode Restrictions

Communication Settings Overview

Communication Format and Speed Settings

Delimiter Settings for Communication

Maintenance and Transportation

Troubleshooting: General Display Messages

Understanding General Balance Display Messages

Lists and explains general display messages that appear on the balance.

Troubleshooting: Error Displays

Error Displays and Their Countermeasures

Lists error displays, their descriptions, and recommended countermeasures.

Appendix: Menu Map Groups

Appendix: Menu Map Groups

Menu Map Overview

Menu Group 1: Calibration and PSC Settings

Details the menu structure for calibration execution and PSC function.

Key Panel and Operation Summary

Key Functions Overview

Summarizes the functions of the balance keys for operation.

Shimadzu UW820S Specifications

General IconGeneral
Capacity820 g
Readability0.01 g
Repeatability (Standard Deviation)0.01 g
Linearity±0.02 g
CalibrationExternal calibration
Operating Temperature5°C to 40°C
DisplayLCD
InterfaceRS-232C
Response TimeApprox. 2 seconds
Power RequirementsAC adapter
Units of Measurementg, ct, oz, lb
Stabilization TimeApprox. 2 seconds

Related product manuals