Questions and Answers

  • R
    ryanacostaAug 20, 2025
    What to do if my Shott BP-30WS-B Heat Pump is running but the water is not heating?
    • J
      Jennifer MoranAug 20, 2025
      If your Shott Heat Pump is running but not heating the water, first ensure that air exits the front part of the heat pump. If the heat pump was just installed, allow 24 to 48 hours to reach the set temperature. If the pool water has significantly cooled since the last use, it may take 24 to 36 hours to reach the desired temperature.
  • K
    Kyle JohnsonAug 22, 2025
    What to do if my Shott Heat Pump displays error message EE b?
    • M
      Mr. George HendersonAug 22, 2025
      If your Shott Heat Pump shows error message EE b, it indicates insufficient water flow. Increase the water flow in the hydraulic circuit that supplies the heat pump and restart after 2 minutes. Alternatively, the flow sensor might be incorrectly connected or defective, so check the connections and replace the sensor if necessary.
  • W
    whitneywilsonAug 25, 2025
    What to do if my Shott BP-30WS-B does not turn on?
    • A
      alexander37Aug 25, 2025
      If your Shott Heat Pump does not turn on, ensure that you have followed all instructions. Additionally, check the mains connection line protection device fuse and the contact switch; reset the switch or replace the fuse if necessary.
  • C
    Christopher AdamsAug 26, 2025
    What does it mean if my Shott Heat Pump displays error message EE 6 and doesn't work?
    • M
      Michael WagnerAug 27, 2025
      If your Shott Heat Pump displays error message EE 6 and does not work, it could be due to several reasons. The compressor temperature might be too high, so wait for it to drop. Alternatively, there could be a refrigerant circuit leak, in which case you should check for leaks with a leak detector and replace any defective parts. Finally, the capillary circuit might be clogged, requiring you to replace it.
  • H
    Heather ChapmanAug 28, 2025
    What to do if my Shott BP-30WS-B is not working and shows error message EE 1?
    • Y
      ylambAug 28, 2025
      If your Shott Heat Pump is not working and displays error message EE 1, the pool temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary.
  • G
    George PerezAug 29, 2025
    Why won't my Shott BP-30WS-B Heat Pump start?
    • Y
      yjohnsonAug 29, 2025
      Your Shott Heat Pump might not start for several reasons. Ensure that the 3 minutes required for pump start have elapsed. If the pool temperature is greater than or equal to the set temperature, the pump will start when the pool temperature is lower. Also, verify that the pump operating mode is set to the required mode.
  • J
    Jason AyersSep 1, 2025
    What to do if my Shott Heat Pump has frost on the plate heat exchanger?
    • G
      George HoodSep 1, 2025
      If there is frost on the plate heat exchanger of your Shott Heat Pump, it could be due to a low ambient temperature or high humidity. You can start a manual defrost. Another possible cause is a pressure refrigerant drop, in which case you should replace the refrigerant.
  • J
    Joshua RaySep 2, 2025
    What to do if my Shott BP-30WS-B is leaking water?
    • B
      Brandon HallSep 3, 2025
      If water is leaking from your Shott Heat Pump, it could be due to condensation accumulation. Put the heat pump in standby; if the leak stops, it's normal condensation. Alternatively, there may be a water leak from the water exchanger or hydraulic unit connection devices, in which case you should tighten the fastening nut.
  • M
    Mr. Michael Kirk MDSep 4, 2025
    What does error message EE 7 on my Shott Heat Pump mean?
    • C
      Christopher MannSep 4, 2025
      If your Shott Heat Pump displays error message EE 7 and doesn't work, it indicates a current dispersion. Replace the defective component, which could be the compressor, fan, four way valve, or electronic board.
  • M
    Mark Roberts IISep 6, 2025
    What to do if my Shott BP-30WS-B Heat Pump displays error message EE c?
    • E
      Evan MurphySep 6, 2025
      If your Shott Heat Pump displays error message EE c, it means the ambient temperature is under -15 [°C]. Wait until the ambient temperature rises to start the heat pump.

Summary

1. General Warnings and Information

3. Technical Specifications

4. Installation

Electrical Connections and Safety

Safe electrical hookup, socket installation, cord replacement, and related safety.

Commissioning and First Start-up

Steps and checks required before initial operation.

5. Operations and Use

Control Panel Basics

Guide to operating the heat pump via its control panel interface.

Functional Parameter Settings

Advanced configuration options for technicians, covering various operational parameters.

6. Control and Safety Devices

7. Maintenance

7.5. Troubleshooting

Shott BP-30WS-B Specifications

General IconGeneral
BrandShott
ModelBP-30WS-B
CategoryHeat Pump
LanguageEnglish

Related product manuals