B P - 3 5 W S - B
B P - 5 0 W S - B
B P - 5 0 H S - A
B P - 8 5 H S - A
B P - 1 0 0 H S - A
Installation manual

Table of Contents

Questions and Answers

  • D
    David LoveAug 20, 2025
    What to do if my Shott BP-35WS-B is running but the water is not heating?
    • E
      Edward MorrowAug 20, 2025
      If your Shott Heat Pump is running, but the water isn't heating, first ensure that air exits the front part of the heat pump. Also, consider that if the heat pump was just installed, it may require 24 to 48 hours to reach the set temperature. If the pool water has significantly cooled since the last use, it could take 24 to 36 hours to reach the desired temperature.
  • C
    courtneyfosterAug 22, 2025
    What to do if my Shott BP-35WS-B Heat Pump does not turn on?
    • J
      Julie GouldAug 22, 2025
      If your Shott Heat Pump doesn't turn on, ensure that you have followed all instructions. Additionally, check the mains connection line protection device fuse and the contact switch. Reset the switch or replace the fuse if necessary.
  • C
    cheryl64Aug 25, 2025
    Why is my Shott BP-35WS-B not working and error message EE 6 is displayed?
    • T
      Tommy GonzalezAug 25, 2025
      If your Shott Heat Pump displays error message EE 6 and isn't working, it could be due to several reasons. The compressor temperature might be too high, so wait until it drops. There could be a refrigerant circuit leak, so check for leaks and replace any defective parts. Alternatively, the capillary circuit might be clogged, in which case it should be replaced.
  • A
    andrewreedAug 27, 2025
    What to do if my Shott BP-35WS-B does not start?
    • X
      Xavier RuizAug 27, 2025
      If your Shott Heat Pump doesn't start, first ensure that the 3 minutes required for pump start have elapsed. If the pool temperature is at or above the set temperature, the pump will only start when the pool temperature drops below the set temperature. Finally, confirm that the pump operating mode is set to the required mode.
  • K
    kelli31Aug 28, 2025
    What to do if my Shott BP-35WS-B does not work and error message EE 1 is displayed?
    • S
      Shelley RogersAug 28, 2025
      If your Shott Heat Pump displays error message EE 1 and isn't working, the pool temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary. You can also replace the control board.
  • J
    John DukeAug 29, 2025
    What to do if my Shott BP-35WS-B Heat Pump does not work and error message EE 2 is displayed?
    • B
      bethany24Aug 29, 2025
      If your Shott Heat Pump displays error message EE 2 and isn't working, the ambient temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary. You can also replace the control board.
  • S
    Stacey AndersenAug 31, 2025
    What to do if my Shott BP-35WS-B is running and error message EE 3 is displayed?
    • W
      weissjohnSep 1, 2025
      If your Shott Heat Pump displays error message EE 3 while running, the compressor temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace if necessary. You can also replace the control board.
  • T
    Theresa DeckerSep 2, 2025
    What does it mean if my Shott BP-35WS-B Heat Pump displays error message EE b?
    • P
      Peter MillerSep 2, 2025
      If your Shott Heat Pump is showing error message EE b, it could be due to insufficient water flow. Increase the water flow in the hydraulic circuit that supplies the heat pump. Alternatively, the flow sensor might be incorrectly connected or defective, in which case you should check the connections and replace the sensor if needed or replace the control board.
  • R
    Ralph RobinsonSep 4, 2025
    What to do if my Shott BP-35WS-B is running and error message EE 4 is displayed?
    • D
      Daniel RussellSep 4, 2025
      If your Shott Heat Pump displays error message EE 4 while running, it could be due to several reasons. The automatic defrost may not have run correctly, so increase water flow at the pump inlet. Alternatively, the plate heat exchanger temperature sensor may be incorrectly connected or defective. Check the sensor resistance value and replace it if necessary. You can also replace the control board.
  • M
    Mark AllenSep 6, 2025
    What to do if my Shott BP-35WS-B does not work and error message EE 8 is displayed?
    • C
      carolyn21Sep 6, 2025
      If your Shott Heat Pump displays error message EE 8 and isn't working, the control board wiring may be defective. Check the wiring or replace the control board.

Summary

General Warnings and Information

CE Declaration

Declaration of conformity with relevant EU directives and harmonised standards.

Warranty Information

General Warranty Conditions

Details the general terms and conditions of the product warranty.

Special Warranty Conditions

Outlines specific conditions for warranty validity and coverage.

Warranty Restrictions

Lists limitations and exclusions applicable to the warranty coverage.

Symbol Key

Safety Regulations for Heated Pools

Energy Saving Tips

General Information

Definitions

Product Presentation

Product Scope

Describes the intended use and application of the SERIES BP heat pumps.

Heat Pump Composition

Technical Specifications

Installation Guide

Inspection Upon Receipt

Instructions for inspecting the heat pump upon delivery and checking packaging integrity.

Safe Handling Procedures

Guidelines for safely handling the heat pump unit during installation and unpacking.

Positioning Requirements

Specifies requirements and considerations for selecting the optimal installation location.

Support and Location Details

Details on selecting a suitable support and the installation site requirements.

Necessary Clearance for Installation

Minimizing Noise Echo

Disposal Information

General Disposal Instructions

Guidelines for the proper disposal of packaging and replaced parts.

Heat Pump Decommissioning

Instructions for safely decommissioning and disposing of the heat pump at end-of-life.

Electronic Waste Disposal

Hydraulic Connections

Hydraulic Connection Warnings

Important warnings and recommendations for performing hydraulic connections safely.

Installation Hydraulic Layout

Illustrates the general layout for connecting the heat pump within the pool's hydraulic system.

Electrical Connections

Mains Connection Socket Installation

Mains Connection Cord Replacement

Commissioning and Preliminary Checks

Commissioning Precautions

Crucial precautions to be taken before starting the heat pump system.

First Start-up Checks

Essential checks to perform before the very first start-up of the heat pump.

Operation and Use

Introduction to Operation

Overview of the heat pump's control system and its energy-saving features.

Control Panel Usage

Detailed explanation of the heat pump's control panel and its interface.

Turning the Heat Pump On

Instructions on how to safely turn on the heat pump using the protection device.

Heat Pump Standby Mode

Explanation of the heat pump's standby mode and what is displayed.

Turning the Heat Pump Off

Procedure for safely turning off the heat pump.

Starting the Heat Pump

Operating Mode Selection

Setting Water Temperature

Minimum Working and Restart Temperatures

Automatic Start Settings

Automatic Standby Settings

Manual Defrost Procedure

Key Lock Function

Sensor Temperature Display

Functional Parameter Settings

Pool Temperature Regulation Range

Sets the acceptable range for pool water temperature regulation.

Automatic Defrost Start Temperature

Configures the ambient temperature at which automatic defrost begins.

Automatic Defrost Stop Temperature

Sets the heat exchanger temperature for stopping the automatic defrost cycle.

Automatic Defrost Repetition Time

Determines the interval between automatic defrost cycles.

Defrost Duration Setting

Sets the time duration for both automatic and manual defrost cycles.

Compressor Protection Temperature

Configures the maximum temperature limit for compressor protection.

Automatic Restart Setting

Enables automatic restart of the previous operating mode after a power outage.

Operating Mode Selection

Selects the primary operating mode of the heat pump (heating, cooling).

Maximum Deviation from Set Temperature

Sets the maximum allowed deviation from the target pool temperature.

Control Mode Selection

Selects the control mode for the heat pump or heater.

Manometer Usage

Control and Safety Devices

Control Devices Overview

Describes the sensors and devices that control the heat pump's operation.

Ambient and Pool Temperature Sensors

Information on ambient and pool water temperature sensors and their function.

Flow Sensor Details

Details the flow sensor used to monitor water flow rate.

Safety Devices

Compressor and Heat Exchanger Temperature Sensors

Describes sensors for monitoring compressor and heat exchanger temperatures.

High Pressure Sensor Function

Explains the function of the high pressure sensor in protecting the compressor.

Low Pressure Sensor Function

Details the low pressure sensor and its role in compressor protection.

Temperature Sensor Resistance Values

Compressor Temperature Sensor Resistance Values

Maintenance Procedures

User Controls and Maintenance

Periodic checks and maintenance tasks that users can perform.

Specialized Technician Controls

Maintenance tasks that require a qualified technician.

Winter Protection

Instructions for protecting the heat pump during the winter season.

Spring Commissioning

Steps for recommissioning the heat pump after winter storage.

Troubleshooting Guide

Spare Parts Information

Special Notes on Part Replacement

Important notes and procedures before replacing parts on the heat pump.

Manometer Replacement

Instructions for safely replacing the manometer on the heat pump.

Pressure Sensor Replacement

Procedure for replacing the pressure sensor, including necessary tools.

Filter and Capillary Replacement

Guidelines for replacing the filter and capillary components.

Frost on Radiator Troubleshooting

Troubleshooting step for frost on the radiator, involving refrigerant pressure check.

Shott BP-35WS-B Specifications