English
7
SYSTEM AND COMPONENT SPECIFICATIONS
RF Carrier Frequency Range
169.445 to 240.000 MHz (Available frequencies depend on
applicable regulations in country where system is used).
Operating Range:100 m (328 ft.) under typical conditions
Audio Frequency Response: 50 to 15,000 Hz, $ 3 dB
Image Rejection: 60 dB typical
Spurious Rejection: > 60 dB typical
System Distortion (ref. 15 kHz deviation, 1 kHz modula-
tion): 0.1% THD typical
Signal/Noise Ratio: 101 dB
Sensitivity: –109 dBm for 12 dB SINAD typical
Operating Temperature Range:
–18° to 57° C (0° to 135° F) NOTE: Battery characteristics
may limit this range.
Battery Life: 18 hours with 9 V alkaline battery (Duracell
MN1604 recommended).
T1, T1G AND T11 BODYPACK TRANSMITTER
SPECIFICATIONS
RF Output 50 mW typical (T1, T1G); 20 mW typical (T11)
Input
Configuration
Unbalanced
Connector Type
1/4 Inch (T1G); 4-pin Miniature Connector (male)
(T1)
Actual
Impedance
1 MΩ
Maximum
Recommended
Input Level*
+3 dBV
Minimum
Recommended
Input Level**
–80 dBV
Connector Pin
Assignments
(T1, T11)
Pin 1:Tied to Ground
Pin 2:Tied to +5 V
Pin 3:Tied to Audio
Pin 4:Tied to 20kΩ Resistor and Audio Ground
Connector Pin
Assignments
(T1G)
Sleeve: Tied to Ground
Tip: Tied to Audio
Dimensions
(T1, T1G)
64 mm H x 106 mm W x 24 mm D
(2.52” H x 4.17” W x 0.95” D)
Dimensions (T11)
83 mm H x 64 mm W x 26 mm D
(3.27” H x 2.50” W x 1.03” D)
Net Weight
(T1,T1G)
96.4g (3.4 oz.)
Net Weight (T11) 79.4g (2.8 oz.)
Power
Requirements
9 V alkaline battery (Duracell MN1604
recommended); 8.4 V NiCd battery optional.
Nominal Current
Drain
30 mA
* Gain Control at minimum
** Gain Control at maximum
T2 HAND-HELD TRANSMITTER SPECIFICATIONS
T2/58(SM58
) T2/(PG58
)
RF Output 50 mW Typical (FCC); 20 mW Typical (ETSI)
Dimensions
236 mm H x 51 mm D
(9.29” H x 2.01” D)
222 mm H x 51 mm D
(8.74” H x 2.01” D)
Net Weight 295 g (10.4 oz.) 266 g (9.4 oz.)
Power Requirement
9 V alkaline battery (Duracell MN1604 recom-
mended); 8.4 V NiCd battery optional.
Nominal Current
Drain
30 mA 30 mA
T3 AND T4N RECEIVER SPECIFICATIONS
T4N T3
Connector 3-Pin XLR (Male) and
1/4” Phone Jack
1/4” Phone Jack
Maximum Output
Levels
1/4”: +5 dBV
XLR: –10 dBV
–6.8 dBV
Nominal Output
Levels
1/4”: –8 dBV
XLR: –30 dBV
–32 dBV
Output
Configuration
Active Balanced Unbalanced
Actual Impedance 3.3 KΩ 1 KΩ
Connector Pin
Assignments
XLR: Pin 1: ground;
Pin 2: hot; Pin 3: cold
1/4”: Tip: hot; Sleeve:
ground.
Tip: hot; Sleeve:
ground
Dimensions (T4N) 41 mm H x 197 mm W x 138 mm D
(1.625” H x 7.77” W x 5.42” D)
Dimensions (T3) 35mm H x 152 mm W x 98 mm D
(1.38”H x 5.98” W x 3.85” D)
Net Weight (T4N) 435 g (15.4 oz.)
Net Weight (T3) 192 g (6.8 oz.)
Power
Requirements
12–18 VDC nominal, 200mA
Power Supply 120 V or 230V AC adaptor with 2.1 mm female
plug
Voltage/Current/
Phantom Power
Protection
Yes Yes
Certification
T1G, T1:Accepted under FCC Parts 74 and 90. Certified by IC
in Canada under TRC-78.
T11: Conforms to European Union directives, eligible to bear CE
marking; meets European Union Requirements. Type Ap-
proval: pr I–ETS 300 422, BZT 17 TR 2019, and BAPT 122
R 1. Meets Requirements of EMC Standard 301-489-1
and –9
T2/PG58, T2/58: Type Accepted under FCC Parts 74 and 90.
Certified by IC in Canada under TRC-78. Conforms to
European Union directives, eligible to bear CE marking;
meets European Union Requirements. Type Approval: pr
I–ETS 300 422, BZT 17 TR 2019, and BAPT 122 R 1. Meets
Requirements of EMC Standard 301-489-1 and –9
T3: Approved under the Notification provision of FCC Part 15.
Certified by IC in Canada under TRC–78.
T4N: Approved under the Declaration of Conformity (DoC)
provision of FCC part 15. Certified by IC in Canada under
RSS-210. Conforms to European Union directives, eleg-
ible to bear the CE marking. Meets Requirements of EMC
Standard 301-489-1 and –9
T11 and T2 Transmitters meet the essential requirements of
the European R&TTE Directive 99/5/EC and are eligible to
carry the CE marking.
O682
T3 and T4 Receivers meet the essential requirements of the
European R&TTE Directive 99/5/EC and are eligible to
carry the CE marking.
Power supply meets the following safety standard:
PS20 Power Supply: UL 1310, CAN/CSA 22.2 No. 223.
PS20E Power Supply: EN 60065/09.93.
PS20UK Power Supply: EN 60065 5th, 1985.