6.2.2.b – Programming of the FLAGs
Tab. 10 is to be used in the programming of the flags for the modality LLL1 – LL2
Tab. 10 – Selection of the operative modality single column - start a volume
FLAG
Display
Operative state / Data visualised
Program
S C - -
State of access to the selection of the programming codes
Advance
S C 0 9
With the key Advance programming code is increased up to 9
Program
L L L 1
Single column modality. If necessary modify the data with Advance
Program
L L - 2
Regeneration by volume. If necessary modify the data with Advance.
Program
0 H L
0 H L 0
Immediate start of the regeneration only by finished volume
Advance
0 H L
0 H L 1
Immediate start of the regeneration by finished volume and by finished time
Program
1 H L
1 H L 0
FLAG not used
Program
2 H L
2 H L 0
Immediate start of the regeneration at the command of the remote start.
See par. 6.5
Advance
2 H L
2 H L 1
Start of the regeneration at the time programmed at the command of the remote start
Program
3 H L
3 H L 0
FLAG not used. Leave programmed at 0
Program
0 C L
0 C L 0
Modality of the litre counter divider. Do not use. See par. 6.6
Program
1 C L
1 C L 0
FLAG not used. Leave programmed at 0
Program
2 C L
2 C L 0
FLAG not used. Leave programmed at 0
Program
3 C L
3 C L 0
Management of management of salt alarm disabled
Advance
3 C L
3 C L 1
Management of management of salt alarm enabled. See par. 6.9
Program
0 d L
0 d L 0
Normal functioning
Advance
0 d L
0 d L 1
Management of the start of the regeneration in the case of inhibit. See par. 6.12
Program
1 d L
1 d L 0
FLAG not used
Program
2 d L
2 d L 0
FLAG not used
Program
3 d L
3 d L 0
FLAG not used
Program
Fast flashing of the display. The programming is memorised in eeprom.