6.2.2.c – List of codes to be programmed
For the programming and the meaning of the codes see par. 6.3. In this modality the programming of the following
codes is recommended:
Tab. 11 – Table of the codes in one single column modality LLL1 – LL–2
Programming of the regeneration cycle ( stop times )
Programming of the litre counter divider ( pre-scaler )
Programming of the duration of the end of cycle impulse and of the litre counter divider of the
dosing pump
Programming of the volume of resin, of the percentage of reserve and of the capacity of exchange
Programming of the hardness value
Initialisation of the system
If the flag 0HL has been programmed with the value 1 to also have the regeneration by time, the programming
recommended varies as follows:
Tab. 12 – Table of the codes in one single column modality LLL1 – LL–2
Programming of the time of regeneration and the interval days between two regenerations
Programming of the regeneration cycle ( stop times )
Programming of the litre counter divider ( prescaler )
Programming of the duration of the end of cycle impulse and of the litre counter divider of the
dosing pump
Programming of the volume of resin, of the percentage of reserve and of the capacity of exchange
Programming of the hardness value
Initialisation of the system
6.2.3 - LLL1 – LL–3 – One single column with mixed time / volume start.
6.2.3.a –Operative characteristics.
In this operative modality, the regeneration starts exclusively when the interval days have passed and at the
programmed time. If the volume of water treated reaches the value calculated for the reserve, the residual days will be
ignored. It is not possible to have the immediate start of the regeneration either because the volume has run out, or
because the value of the reserve has been reached. The control on the reserve is automatic and cannot be dis-
activated.
The control on the remote start is available, and can start up the regeneration both immediately and deferred to the
programmed time, based on the content of the flag 2HL.
In this operative modality the possibility of using the cam with the stand-by is not available.