3. Press the SET pushbutton.
4. Use the plus or minus pushbutton to select dSP.
THR
PRO
TCH
PWR
Q
5. Press the SET pushbutton.
THR
PRO
TCH
PWR
Q
6. Use the plus or minus pushbutton to select the direction in which the segment dis‐
play points.
THR
PRO
TCH
PWR
Q
7. Press the SET pushbutton.
7.9 Other indicators and functions
Incorrect teach-in
THR
PRO
TCH
PWR
Q
In the event of a teach-in failure, Err appears on the display and the Q LED and TCH LED
flash.
Control panel locked
THR
PRO
TCH
PWR
Q
If the device is undergoing an internal process (e.g., reading or storing parameter sets
or teaching in via IO-Link), the control panel is locked and the device shows “bSY” on
the segment display.
Short-circuit and overcurrent detection
THR
PRO
TCH
PWR
Q
In the event of a short-circuit, Err appears on the display and the Q LED flashes.
Live measured value (run mode)
In run mode, the device displays the remission value currently being measured as a
digit.
7 OPERATION
40
O P E R A T I N G I N S T R U C T I O N S | KTS/KTX Prime 8020708.ZMT3/ | SICK
Subject to change without notice

Other manuals for SICK KTX Prime

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK KTX Prime and is the answer not in the manual?

SICK KTX Prime Specifications

General IconGeneral
BrandSICK
ModelKTX Prime
CategorySecurity Sensors
LanguageEnglish

Related product manuals