| Number of fields | 128 |
|---|---|
| Protective field range | Up to 5.5 m |
| Number of monitoring cases | 128 |
| Number of simultaneously monitored protective fields | 8 |
| Number of simultaneously monitored warning fields | 8 |
| Angular resolution | 0.1° |
| Response time | 30 ms |
| Interfaces | PROFINET |
| Safety integrity level | SIL3 (IEC 61508) |
| Performance level | PL e (ISO 13849-1) |
| Ambient operating temperature | +50 °C |
| Protection class | IP65 |
| Supply voltage | 24 V DC |
| Storage temperature | –25 °C ... +70 °C |
| Housing material | plastic |
DANGER: Hazard due to lack of effectiveness of the protective device. Non-compliance can lead to dangerous states.
Procedure for relocating the system plug to the rear of the safety laser scanner for better cable management.
Pin assignment details for the M12 male connector used for voltage supply.