Do you have a question about the SICK microScan3 - PROFINET and is the answer not in the manual?
Number of fields | 128 |
---|---|
Protective field range | Up to 5.5 m |
Number of monitoring cases | 128 |
Number of simultaneously monitored protective fields | 8 |
Number of simultaneously monitored warning fields | 8 |
Angular resolution | 0.1° |
Response time | 30 ms |
Interfaces | PROFINET |
Safety integrity level | SIL3 (IEC 61508) |
Performance level | PL e (ISO 13849-1) |
Ambient operating temperature | +50 °C |
Protection class | IP65 |
Supply voltage | 24 V DC |
Storage temperature | –25 °C ... +70 °C |
Housing material | plastic |