3.3.2 Compatible sensor types
Table 2: Compatible sensor types
Sensor type Description Examples
Safety sensors with
monit
ored semiconduc‐
tor output (OSSD)
Safety sensors with dual-channel
cross-circuit monitored semi-con‐
ductor outputs
Safety controllers with monitored
semi-conductor outputs
T
ransponder safety switch
e.g., Sistra
Safety light curtains, e.g.
deTec4
Safety laser scanner, e.g.,
microScan3, nanoScan3
3.3.3 External device monitoring
The feedback current path is used as external device monitoring for the monitoring by
t
he base device.
3.3.4 Status indicators
LEDs
CH1
CH2
13
23
31
I1
14
24
32
I2
A2
RELY
1
3
2
3
3
1
I1
14
2
4
3
2
I2
A2
RELY
CH1
CH2
OSSD1
1085343
Figure 2: LEDs
The labeled positions are only partially assigned LEDs. The positions and their labels
(e
xcept the top 2 lines) also indicate the assignment of the terminals on the front connec‐
tor.
Table 3: Safety relay indicators
Labeling Color Function
CH1 Green OSSD1 safety capable input