Table 3: RFH5xx: scope of delivery
No. of
units
Component Remarks
1 Type of device ordered in
welded plastic bag
RFH505 or RFH510:
•
Each with 2 nuts and 2 spring washers
•
Without bracket
RFH515:
•
With clamping bracket, without fixing screws for
base
All devices:
•
Without connecting cable
•
Electrical connection: the M12 male connector
1)
is not closed with a protective element.
1 Printed safety notes (safety
information)
The document contains safety information on han‐
dling the device as well as the SICK product page
link for online access to the operating instructions
1 Printed Technical Information
RFH5xx Regulatory Compliance
Information
The document includes information on:
•
Country or groups of countries (region) for which
a device certification exits
•
Conformities fulfilled
•
If applicable, country-specific operating condi‐
tions to be upheld when operating devices
1)
The device achieves type-specific enclosure rating IP67 or IP68 when the head of the IO-Link connecting
cable is attached to the male device connector and is tightly fastened.
3.2.4 Product features and functions (overview)
Table 4: Overview of product features and functions of the device
Product feature/func‐
tion
Characteristic
Safety and ease of
use
•
Safe identification of objects in tight spaces
•
Clearly defined detection ranges of the device variants enable relia‐
ble singulation of transponders, even at very small distances from
objects to the device.
•
Rugged, compact metal or plastic housing with metric dimensions,
CE marking (Europe)
•
Output of the read result as well as error messages in IO-Link
format
•
Operating data request. In the event of an error: output of codified
error messages
•
Color-coded status display of operational statuses via LEDs
•
Low power consumption
•
Wide supply voltage range
•
Large ambient operating temperature range
Convenient operation
and configuration
•
Device configuration for demonstrating the operating principle of
the device in the SICK SiLink2 IO-Link master with SOPASET config‐
uration software
•
Device configuration for operational use via the system control
(PLC) using an IO-Link master and the type-specific IO-Link device
description file (IODD) of the RFH5xx in the configuration tool of the
PLC
•
Optional function blocks for easier integration of the device into PLC
programs
Write/Read trigger
•
Via PLC
Radio interface
•
Integrated antenna
PRODUCT DESCRIPTION 3
8025309/1KDE/2023-12-19 | SICK O P E R A T I N G I N S T R U C T I O N S | RFH5xx
19