- LLaura RushJul 26, 2025
If the SICK Scanner requires a reset, operate the control switch for restart or reset.
How to reset SICK S3000?
If the SICK Scanner requires a reset, operate the control switch for restart or reset.
What to do if my SICK S3000 shows a system error?
If the SICK Scanner indicates a system error, note the error code on the 7-segment display or use the CDS diagnostics tool. Then, power off the S3000 for at least 2 seconds before turning it back on.
What to do if there is a fault in the external device monitoring (EDM) of my SICK S3000 Scanner?
If the SICK Scanner displays a fault in the external device monitoring (EDM), verify that the contactors are functioning correctly and properly wired. If '?' is displayed, switch off the device, wait at least 3 seconds, and then switch the voltage supply back on.
Why does my SICK Scanner show a temperature error?
If the SICK Scanner gives a temperature error, check whether the device is being operated within the permissible ambient conditions.