The following table shows the available users and their initial password:
Table 7: User / Passwords
User Initial password Role
Run (none) Read configuration
Maintenance main Read and write configuration
Please see "Settings", page 25 for details on changing passwords.
NOTE
As of firmware version 1.2.0, you are automatically prompted to change the password
for the “Maintenance” user when logging in for the first time. Please remember this
password. If you have changed and forgotten the password, contact SICK Service.
If you click Login, you can also change the password of the logged-in user.
NOTE
In terms of cybersecurity of the device, changing the default password of the “Mainte‐
nance” user is strongly recommended.
7.2.3 STATUS page
The STATUS page is the home page for the SIG200. It provides an overview of the
current module status and device function.
Figure 4: Status page
The page displays the parameterization of pin 2 (DI) and pin 4 (C/DI/DO) for each port.
The LEDs in the SIG200 figure change their state depending on the current state of the
connected device. The ports correspond to the IO link, input or output settings defined
on the CONFIGURATION (parameterization) page. The port designations correspond to the
user-defined port designations defined on the CONFIGURATION (parameterization) page.
The POWER LED shown in the figure on the left is normally always green to indicate that
the SIG200 is switched on.
The AUX LED is used for the FIND ME (Identify) function.
ACT/LINK1 + 2 indicate if there is Ethernet network connection on either port.
7
SIG200 CONFIGURATION
18
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200 8024482.1FJ7 /2022-05-31 | SICK