NOTE
Note that the LED displays do not work in real time. When the SIG200 is started for the
first time, the device has an initialization time after switching on of approx. 70seconds
7.2.4 IDENTIFICATION page
The IDENTIFICATION page provides detailed information about the connected SIG200.
These include the product name, serial number and firmware version.
7.2.5 CONFIGURATION page (parameterization)
On the IO-Link Ports tab, the port parameterization for ports S1 to S4 can be changed.
In addition, an IODD file can be uploaded from your computer and assigned to one of
the SIG200 ports (S1 to S4). Therefore, the IODD XML file and the referenced device
image must be packed into a ZIP archive. This follows the same convention used by
the IO-Link community (IODD Finder) and is the preferred method for retrieving the
corresponding device IODDs. In addition, the single IODD can be uploaded as XML file.
Other settings such as the minimum cycle time or the assignment of port designations
can also be made on this page.
On the IO-Link Devices tab there is a page for each IO-Link port (S1-S4). This tab
displays the IODD view, device info and parameter data for each IO-Link device. The
page visualization when an IODD was already uploaded to the user interface is different
to the visualization of the IO-Link device without uploaded IODD file. For a more conven‐
ient use it is recommended to upload the relevant IODD file for the IO-Link devices.
Figure 5: CONFIGURATION page (parameterization)
7.2.5.1 Gateway
The Ethernet settings can be configured on the Gateway tab.
SIG200 CONFIGURATION 7
8024482.1FJ7 /2022-05-31 | SICK O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
19
Subject to change without notice