0
10
(0.39)
20
(0.79)
0
Minimum object height in mm (inch)
Distance in mm (inch)
Recommended sensing range for
the best performance
30
(1.18)
y
x
450
(17.72)
350
(13.78)
250
(9.84)
150
(5.91)
50
(1.97)
2
6%/6%
90%/6%
33
6%/6%
90%/6%
6%/6%
90%/6%
1
Example:
Reliable detection of the object
Black background (6 % remission factor)
Distance of sensor to background x = 300 mm
Required minimum object height y = 10 mm
For all objects regardless of their colors
Background
x
y
Figura 16: Curva caratteristica, WTM10L-xxxxx2
0
Distance in mm (inch)
1
2
3
C/D
A
B
Recommended sensing range for
the best performance
450
(17.72)
350
(13.78)
250
(9.84)
150
(5.91)
50
(1.97)
25
25
400
300
25
220
Figura 17: WTM10L-xxxxx2
1
Oggetto nero, coefficiente di riflessione 6%, Modalità 1: Velocità
2
Oggetto nero, coefficiente di riflessione 6%, Modalità 2: Standard
3
Oggetto nero, coefficiente di riflessione 6%, Modalità 3: Precisione
A Distanza di lavoro min. in mm
B Distanza di lavoro max. in mm
C Campo visivo
D Impostazione della soglia di commutazione dell'intervallo per l'eliminazione dello
sfondo
blu Intervallo di distanza di lavoro raccomandato per massime prestazioni
6.4 Impostazioni
Configurazione di fabbrica
Le seguenti configurazioni sono preconfigurate:
Tabella 11: Configurazioni di fabbrica
Modalità di rilevamento BGS
Modalità di funzionamento Modalità standard
ISTRUZIONI PER L’USO