EasyManua.ls Logo

SICK WTM4S - Page 82

SICK WTM4S
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0
300
(11.81)
200
(7.87)
100
(3.94)
400
(15.75)
500
(19.69)
600
(23.62)
0
y
x
y
x
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission factor)
Example:
Safe suppression of the background
White background (90 %)
Black object (6 % remission factor)
Set sensing range x = 300 mm
Needed minimum distance to white
background y = 17 mm
Distance in mm (inch)
Recommended sensing range for
the best performance
40
(1.57)
32
(1.26)
24
(0.94)
16
(0.63)
8
(0.31)
2
6%/90%
90%/90%
4
3
18%/90%
1%/90%
1
Figura 9: WTM4S-xxxxx8xx, MultiMode 1+6
4
2
3
1
0
Distance in mm (inch)
300
(11.81)
200
(7.87)
100
(3.94)
400
(15.75)
500
(19.69)
600
(23.62)
3504/10
1804/10
4/10
4/10
450
500
D
C
A B
BluePilot
E
F
Recommended sensing range for
the best performance
Figura 10: WTM4S-xxxxx8xx, MultiMode 1+6
1
Objeto ultra negro, nivel de remisión del 1%
2
Objeto negro, 6% de reflectividad
3
Objeto gris, 18% de reflectividad
4
Objeto blanco, 90% de reflectividad
A Distancia de conmutación mín. en mm
B Distancia de conmutación máx. en mm
C Campo de visión
D Ajuste del umbral de conmutación de rango para la supresión de fondo
E Indicación de distancia de conmutación
F Elemento de presión y rotación
Azul Rango recomendado de distancia de conmutación para un mejor rendimiento
Comprobar el funcionamiento con ayuda de véase tabla 5, página 13. Si la salida
digital no se comporta según véase tabla 5, página 13, comprobar las condiciones de
aplicación.
INSTRUCCIONES DE USO
82
I N S T R U C C I O N E S D E U S O | WTM4S 8028212/2023/10/20 | SICK
Sujeto a cambio sin previo aviso
es

Table of Contents

Related product manuals