11
Last update: 01.08.2013
Operating instructions
GENIUS
Disposing of batteries
The law requires that all spent standard and rechargeable batteries be returned to their manufacturer; they must not be
disposed of as household waste. Dispose of the batteries as required by the relevant authorities. Hand them in for recycling.
These batteries will be recycled as they may contain e.g. nickel oxide hydroxide and cadmium (Ni-Cd), lead (Pb), cadmium
(Cd) or mercury (Hg).
Malfunctions
Important: If the problem cannot be rectified as described below, do not open the GENIUS door lock or attempt to
repair the system under any circumstances. Get the system repaired by a qualified specialist.
Malfunction Possible causes Action
The wireless receiver is not recei-
ving a signal
- Battery in handheld transmitter is too
low.
- Other systems (e.g. wireless headpho-
nes) are transmitting signals of the
same frequency (433.92 MHz).
- Range too small.
Replace battery
Switch off other systems
(Fit wire aerial to wireless receiver)
The door does not lock - Door is not fully closed.
- Door contact is misaligned.
- Switch set to day mode
Shut the door
Check door contact
Check switch
GENIUS locks when door is ajar Lock face plate or door is pre-magnetised Invert magnet on frame side
(reverse polarity)
Not functioning Circuit breaker in main fuse box has
tripped
Reset circuit breaker
Acoustic signal (approx. 8 sec.);
door does not lock
- Jam caused by foreign body or damage
in lock area
Remove foreign body from lock area.
A short beep is heard Locking action obstructed *1(stiffness,
or jam due to failure to use free-running
cylinder)
Confirm the fault by unlocking the door
manually (using the cylinder key), pressing
an external "open" button, or opening the
door.
*1 If the door repeatedly fails to lock correctly, the locking action should be checked manually. To do this, use the cylinder
key to lock and unlock the door with the door shut. It must be possible to turn the key through two fulls turns without pushing
or pulling the door or the door handle. If a free-running cylinder has not been installed, the fixed catch in the cylinder will
cause a malfunction in the GENIUS door lock when the key is removed from the lock.