EasyManua.ls Logo

Siemens 6EP1437-3BA10 User Manual

Siemens 6EP1437-3BA10
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SITOP PSU8200 3ph
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
___________________
SITOP power supply
SITOP PSU8200 3ph
Manual
SITOP PSU8200 24 V/20 A
6EP3436
-8SB00-0AY0
SITOP PSU8200 24 V/40 A
6EP1437
-3BA10
11.2014
C98130
-A7638-A1-2-7629
Overview
Notes on safety
1
Description, device design,
dimension drawing
2
Mounting/removing
3
Mounting position, mounting
clearances
4
Installation
5
Technical data
6
Safety, approvals, EMC
7
Ambient conditions
8
Applications
9
Environment
10
Service & Support
11
Question and Answer IconNeed help?

Do you have a question about the Siemens 6EP1437-3BA10 and is the answer not in the manual?

Siemens 6EP1437-3BA10 Specifications

General IconGeneral
Output Voltage24 V DC
Output Current10 A
Power Rating240 W
Efficiencyup to 93%
Protection ClassIP20
Weight1.2 kg
Dimensions125 mm x 125 mm x 150 mm
Operating Temperature-25°C to +70°C

Summary

Overview

Notes on Safety

Correct Handling of Devices

Provides safety instructions for handling electrical devices and preventing injury or damage.

Description, Device Design, Dimension Drawing

Device Description

Details the SITOP PSU8200 3ph as a primary-switched power supply with regulated DC voltage.

Connections and Terminal Designation

Explains how to connect the line input and output terminals, with associated terminal data.

Mounting/Removing

Mounting and Removal

Instructions on how to mount the SITOP PSU8200 on a DIN rail and how to remove it.

Installation

Line-side Connection

Explains how to connect the 3-phase AC line supply, including protection requirements.

Output-side Connection

Details the connection of loads to the SELV DC output terminals and grounding considerations.

Technical Data

Input

Presents technical specifications related to the AC input voltage, range, and frequency.

Output

Provides technical data for the DC output, including voltage, current, regulation, and ripple.

Efficiency

Shows efficiency curves and power loss data at rated conditions for different input voltages.

Applications

Parallel Connection to Increase Power Rating

Explains how to connect multiple SITOP PSU8200 units in parallel to boost power output.

Parallel Connection for Redundancy

Describes using redundancy modules for higher availability and fault tolerance of the 24 V supply.

Series Connection for Increased Voltage

Details connecting two 24 V units in series to achieve 48 V DC output.

Overload Protection in the 24 V Output Circuit

Discusses overload protection methods and the use of selectivity modules for branch monitoring.

Service & Support

Related product manuals