What does unknown parameter mean on Siemens UPS?
- PPatrick HessSep 6, 2025
Attempting to set a parameter that is not known by Siemens DC UPS.
What does unknown parameter mean on Siemens UPS?
Attempting to set a parameter that is not known by Siemens DC UPS.
Why is buffer mode not possible on my Siemens UPS?
If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
How to fix Siemens UPS device temperature too low?
If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
Why Siemens UPS input voltage is too high?
Siemens DC UPS is not operational.
Why is the battery not available on my Siemens 6EP4134-3AB00-2AY0 Power Supply?
The Siemens Power Supply is attempting to access a battery that is not available because it was never connected, or communication with this battery was interrupted.
What does EEPROM write error mean on Siemens UPS?
The Siemens UPS device is defective.
What does wrong parameter mean on Siemens UPS?
The parameter value lies outside the valid range on your Siemens UPS.
What does wrong checksum mean on Siemens UPS?
Communication disrupted with your Siemens UPS.
What causes 'Communication error: Wrong length field' on Siemens 6EP4134-3AB00-2AY0?
This error means there's a syntax error in the command sent to the Siemens Power Supply.
What does insufficient charge level mean on Siemens UPS?
The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.
Provides a general description of the DC-UPS modules and their capabilities.
Details crucial safety precautions for operating electrical devices and handling them properly.
Describes the SITOP UPS1600 and SITOP UPS1100 modules, their features, and integration.
Details the SITOP UPS1600 DC-UPS modules, their design, and mounting requirements.
Details the SITOP UPS1100 battery modules, their components, and communication with the UPS1600.
Explains how to integrate, parameterize, and diagnose SITOP UPS1600 using SIMATIC STEP 7 in TIA Portal.
Details error codes, severity, and help text for hardware faults and internal errors.
Provides instructions for mounting and removing the SITOP UPS1600 devices on mounting rails.
Specifies protection class, degree of protection, and test voltage requirements for the devices.
| Input Voltage Range | 85-264 V AC |
|---|---|
| Output Voltage | 24 V DC |
| Efficiency | up to 93% |
| Protection Class | IP20 |
| Operating Temperature Range | -25 to +70 °C |