What does unknown parameter mean on Siemens UPS?
- BBrian PalmerSep 6, 2025
Attempting to set a parameter that is not known by Siemens DC UPS.
What does unknown parameter mean on Siemens UPS?
Attempting to set a parameter that is not known by Siemens DC UPS.
Why is buffer mode not possible on my Siemens UPS?
If buffer mode is not possible on your Siemens UPS, check settings, cabling, fuse, and battery voltages.
How to fix Siemens UPS device temperature too low?
If the Siemens UPS reports a critically low device temperature, ensure a higher ambient temperature.
Why Siemens UPS input voltage is too high?
Siemens DC UPS is not operational.
Why Siemens UPS shows no software update?
Cannot execute the sent command because no software update has been started on your Siemens UPS.
What does EEPROM write error mean on Siemens UPS?
The Siemens UPS device is defective.
What does wrong parameter mean on Siemens UPS?
The parameter value lies outside the valid range on your Siemens UPS.
What does wrong checksum mean on Siemens UPS?
Communication disrupted with your Siemens UPS.
What does wrong update mean on Siemens UPS?
An attempt was made to update the software on your Siemens UPS with an invalid update file. The update file is probably too old.
What does insufficient charge level mean on Siemens UPS?
The battery charge level is presently too low on your Siemens UPS to reach the set buffer capacity.
Product Type | Power Supply |
---|---|
Output Voltage | 24 V DC |
Output Current | 10 A |
Power Rating | 240 W |
Protection Class | IP20 |
Mounting | DIN Rail |
Width | 125 mm |
Depth | 125 mm |
Operating Temperature | -25 to +70 °C |
Provides essential safety warnings and guidelines for handling electrical devices and preventing damage.
Details the SITOP UPS1600 and UPS1100 devices, including their features and functions.
Introduces software tools and general concepts for engineering and remote access.
Guides on using SIMATIC STEP 7 in TIA Portal for SITOP UPS1600 integration and configuration.
Covers SITOP UPS Manager functions for configuration, monitoring, and protection of UPS systems.
Explains accessing and configuring the SITOP UPS1600 via its web server interface.
Details the activation and configuration of the OPC UA server for remote data access.
Lists common hardware faults, error types, severity, alarm texts, and help explanations.
Provides instructions for mounting and removing the SITOP UPS1600 on mounting rails.
Explains how to mount and remove SITOP UPS1100 modules, including hazardous zone considerations.
Guides on connecting the 24 V DC supply to the input terminals of the SITOP UPS1600.
Details connecting loads to the output terminals, ensuring correct cable dimensioning.
Explains how to connect SITOP UPS1600 to SITOP UPS1100 battery modules via BAT terminals.